Message, Description, Recommended Action, Do not, RAM. Then run the Array Configuration
View all HP ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
3-46 Compaq ProLiant 8500 Server Maintenance and Service Guide Table 3-21 ADU Diagnostic Messages continued Message Description Board not attached Array controller configured for use with array accelerator board, but one is not attached. Configuration signature is zero. ADU detected that nonvolatile RAM contains a configuration signature of zero. Old versions of the System Configuration Utility could cause this. Configuration signature mismatch Array accelerator board configured for a different array controller board. Configuration signature on array accelerator board does not match the one stored on the array controller board. Controller communication failure occurred. Controller communication failure occurred. Controller detected. NVRAM configuration not present EISA nonvolatile RAM does not contain a configuration for this controller. Controller firmware needs upgrading Controller firmware is below the latest recommended version. Controller is located in special "video" slot. Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly. Controller is not configured. Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. ADU examines each physical drive and looks for drives that have been moved to a different drive bay. Recommended Action Attach array accelerator board to array controller. Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM. To recognize the array accelerator board, run the Array Configuration Utility. ADU was unable to successfully issue commands to the controller in this slot. Run the System Configuration Utility to configure the nonvolatile RAM. Run Options ROMPaq to upgrade the controller to the latest firmware revision. Install the controller in a different slot and run the System Configuration Utility to configure the controller and nonvolatile RAM. Then run the Array Configuration Utility to configure controller. Look for messages indicating which drives have been moved. If none appear and drive swapping did not occur, run the Array Configuration Utility to configure the controller and run the System Configuration Utility to configure nonvolatile RAM. Do not run either utility if you believe drive swapping has occurred. continued