HP ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 126
Run the System Configuration Utility to, FYI: Drive bay X is
View all HP ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
3-48 Compaq ProLiant 8500 Server Maintenance and Service Guide Table 3-21 ADU Diagnostic Messages continued Message Description Drive (bay) X was inadvertently replaced. The physical drive was incorrectly replaced after another drive failed. Drive Monitoring features are unobtainable. Drive Monitoring is NOT enabled for SCSI Port X Drive ID X. Drive timeout occurred on physical drive bay X. Drive X indicates position Y. ADU was unable to get monitor and performance data due to fatal command problem, such as drive timeout, or unable to get data because these features are not supported on the controller. The monitor and performance features have not been enabled on this drive. ADU issued a command to a physical drive and the command was never acknowledged. Message indicates physical drive that appears to be scrambled or in a drive bay other than the one for which it was originally configured. Duplicate write memory error Error occurred reading RIS copy from SCSI Port X Drive ID X FYI: Drive (bay) X is non-Compaq supplied. Identify controller data did not match with NVRAM. Data could not be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a data loss situation. An error occurred while ADU was trying to read the RIS from this drive. The installed drive was not supplied by Compaq. The identify controller data from the array controller did not match the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the System Configuration Utility was not run. Recommended Action Replace the drive that was incorrectly replaced and replace the original drive that failed. Do not run the System Configuration Utility and try to reconfigure because data will be lost. Check for other errors (timeouts, and so on). If no other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Run the System Configuration Utility to initialize the monitor and performance features. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Examine the graphical drive representation on ADU to determine proper drive locations. Remove drive X and place it in drive position Y. Rearrange the drives according to the ADU instructions. Replace the array accelerator board. If there were multiple errors, this drive may need to be replaced. If problems exist with this drive, replace it with a Compaq drive. Check the identify controller data under the Inspect Utility. If the firmware version field is the only difference between the controller and nonvolatile RAM data, this is not a problem. Otherwise, run the System Configuration Utility. continued