HP ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 145
Server Health Logs, ASR-2 Integrated Management Log Messages, Table 3-26
View all HP ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Diagnostic Tools 3-67 Server Health Logs In some servers, Server Health Logs are replaced by the IML, if it is supported. See "Integrated Management Display" in this chapter for more information. Server Health Logs contain information to help identify and correct any server failures and to correlate hardware changes with server failure. Server Health Logs are stored in nonvolatile RAM and consist of the Critical Error Log and the Revision History Table. If errors occur, information about the errors is automatically stored in the Critical Error Log. Whenever boards or components that support revision tracking are updated to a new revision, the Revision History Table is updated. ASR-2 Integrated Management Log Messages The Integrated Management Log (IML) or Critical Error Log for Server Health Logs records memory errors, as well as catastrophic hardware and software errors that cause the system to fail. This information helps to quickly identify and correct the problem, thus minimizing downtime. You can view the IML or Critical Error Log through the Compaq Insight Manager. The Diagnostics Utility either resolves the error or suggests corrective action in systems that do not support event logs. The IML or Critical Error Log identifies and records all of the errors detailed in Table 3-26. Table 3-26 ASR-2 IML or Critical Error Log Messages Message Abnormal Program Termination ASR-2 detected by ROM ASR-2 Test Event Automatic Server Recovery Base Memory Parity Error Automatic Server Recovery Extended Memory Parity Error Automatic Server Recovery Memory Parity Error Automatic Server Recovery Reset Limit Reached Battery Failing Description The operating system has encountered an abnormal situation that has caused a system failure. An ASR-2 activity has been detected and logged by the system ROM. The System Configuration Utility generated a test alert. The system detected a data error in base memory following a reset due to the Automatic Server Recovery-2 (ASR-2) timer expiration. The system detected a data error in extended memory following a reset due to the ASR-2 timer expiration. The system ROM was unable to allocate enough memory to create a stack. Then it was unable to put a message on the screen or continue starting the server. The maximum number of system resets due to ASR-2 timer expiration has been reached, resulting in the loading of Compaq utilities. Low system battery warning. Replace battery within seven days to prevent loss of nonvolatile configuration memory. Failure of the battery supporting the system's nonvolatile RAM is imminent. continued