HP ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 86
Table 3-2, POST Error Messages, Error Code, Audible Beeps, Probable Source of Problem
![]() |
View all HP ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
3-8 Compaq ProLiant 8500 Server Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Critical Fan Failure None Detected - System Shutting Down System Halted ECC Multiple Bit Error None Detected in DIMM: FATAL ROM ERROR: The System ROM is not properly programmed 1 long, 1 short Initialization failure. None Re-seat the processor and Processor Power Module before attempting replacement Invalid electronic None serial number No SCSI Devices None Detected Non-System disk None or disk error Parity Check 2 None (RESUME - F1 key) None (Run System None Configuration Utility - F10 key) Probable Source of Problem A critical fan is not spinning. Recommended Action 1. Check fans. 2. Check fan cable connections. A memory module failure generated a multiple bit error that could not be corrected. The System ROM is not properly programmed. Processor was not fully seated. A processor internal failure occurred. Run Compaq Diagnostics and replace failed memory module as indicated. Flash the ROM as explained in Chapter 6, ROMPaq Disaster Recovery Options, or call a Compaq authorized service provider. 1. Reseat the processor. 2. Replace the processor if the failure recurs. Serial number in BIOS is incorrect. No SCSI devices are connected to the boot controller. No bootable disk partition was found on the boot drive. A PCI device generated a parity error 2. As indicated to continue A configuration error occurred during POST. Run the server setup utility to program serial number. Verify configuration. Check SCSI cable, attached drives, and SCSI IDs. 1. Remove diskette from diskette drive. 2. Check controller order in server setup utility. 3. Check boot order in server setup utility. 4. Reinstall operating system. Remove recently added PCI adapters. Re-add the adapters one at a time to determine which is generating errors. Replace the failed device. Press F1. Press F10 to run server setup utility. continued
![](/manual_guide/products/hewlettpackard-proliant-8500-proliant-8500-servers-maintenance-service-guide-083d638/86.png)