HP ProLiant SL165z HP ProLiant SL165z G6 Server Maintenance and Service Guide - Page 74

If you have changed any switches on the system board, verify that each one is properly set.

Page 74 highlights

 The server and monitor are both turned on. The bicolor power status LED indicator on the front panel must be green.  The monitor's contrast and brightness settings are correct.  All internal cables are properly connected and all boards firmly seated.  The processor is fully seated in its socket on the system board.  The heat sink is properly installed on top of the processor.  All memory modules are properly installed. If the POST failure occurs after installing an accessory, perform the following steps: 1. Perform the pre-installation procedure. 2. If necessary, remove any expansion boards, assemblies, or cables that prevent access to the system components. 3. Check the following conditions: a. If you have installed an expansion board, verify that the board is firmly seated in its slot and any switches or jumpers on the board are properly set. Refer to the documentation provided with the expansion board. b. All internal cabling and connections are in their proper order. c. If you have changed any switches on the system board, verify that each one is properly set. 4. Perform the post-installation procedure. 5. Turn on the monitor. 6. If the server still does not work, repeat step 2. 7. Remove all accessories, except the primary boot hard disk drive. 8. Repeat steps 4 and 5. If the server now works, replace the boards and accessories one at a time to determine which one is causing the problem. Diagnostic tools and Setup Utilities 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Diagnostic tools and Setup Utilities
74
The server and monitor are both turned on. The bicolor power status LED indicator on the front
panel must be green.
The monitor's contrast and brightness settings are correct.
All internal cables are properly connected and all boards firmly seated.
The processor is fully seated in its socket on the system board.
The heat sink is properly installed on top of the processor.
All memory modules are properly installed.
If the POST failure occurs after installing an accessory, perform the following steps:
1.
Perform the pre-installation procedure.
2.
If necessary, remove any expansion boards, assemblies, or cables that prevent access to the
system components.
3.
Check the following conditions:
a.
If you have installed an expansion board, verify that the board is firmly seated in its slot and
any switches or jumpers on the board are properly set. Refer to the documentation provided
with the expansion board.
b.
All internal cabling and connections are in their proper order.
c.
If you have changed any switches on the system board, verify that each one is properly set.
4.
Perform the post-installation procedure.
5.
Turn on the monitor.
6.
If the server still does not work, repeat step 2.
7.
Remove all accessories, except the primary boot hard disk drive.
8.
Repeat steps 4 and 5.
If the server now works, replace the boards and accessories one at a time to determine which
one is causing the problem.