Table 18 Power Supply Specifications Item Dimensions (H x W x L) Weight (approximate) Input requirements: Rated input voltage Normal line voltage Line frequency Rated input current BTU rating Power supply output power: Rated steady state power Maximum peak power Temperature range: Operating Storage/Shipping Relative humidity: Operating Non-operating Description 1.515" (H) x 3.4" (W) x 7.736" (L) excluding card edge connector. 3 pounds 90 VAC to 264 VAC 100 VAC to 120 VAC / 200 VAC to 240 VAC 50Hz - 60Hz Max: 10A N/A 460W /750W/1200W N/A +5℃ to +50℃ -40℃ to +85℃ 5% to 95% relative humidity, non-condensing. 5% to 95% relative humidity, non-condensing Physical and Operating Specifications 77
Physical and Operating Specifications
77
Table 18
Power Supply Specifications
Item
Description
Dimensions (H x W x L)
1.515” (H) x 3.4” (W) x 7.736” (L) excluding card
edge connector.
Weight (approximate)
3 pounds
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC / 200 VAC to 240 VAC
Line frequency
50Hz – 60Hz
Rated input current
Max: 10A
BTU rating
N/A
Power supply output power:
Rated steady state power
Maximum peak power
460W /750W/1200W
N/A
Temperature range:
Operating
Storage/Shipping
+5
℃
to +50
℃
–40
℃
to +85
℃
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing.