HP ProLiant SL165z HP ProLiant SL165z G6 Server Maintenance and Service Guide - Page 76

Table 15, Components, Description, ATX Advanced Technology Extended

Page 76 highlights

Table 15 Hardware Specifications Item Thermal solution Table 16 Physical Dimensions Item System board platform System board dimension Server dimensions Rack Server weight Table 17 Environmental Specifications Item Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Altitude: Operating Non-operating Thermal output (maximum operating) Acoustic emissions Normal configuration Components Four 80mm system fans Description ATX (Advanced Technology Extended) 12''x13.5'' 448W X87.9H X 714.7D (mm) Basic Configuration ( excludes keyboard and monitor): 20 kg Description +10 to +35° (+50 to +95°F) -30 to 60° (-22 to 140°F) -30 to 60° (-22 to 140°F) 38.7° (101.7°F) 10% to 90% (non-condensing) 5% to 95% 5% to 95% 0 to 3049 meters (0 to 10,000 ft) 0 to 9146 meters (0 to 30,000 ft) 392 W/hr LWad: 6.7 Bels (operating at room temperature) LWad: 6.7 Bels (Idle at room temperature) Physical and Operating Specifications 76

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Physical and Operating Specifications
76
Table 15
Hardware Specifications
Item
Components
Thermal solution
Four 80mm system fans
Table 16
Physical Dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
12’’x13.5’’
Server dimensions
Rack
448W X87.9H
X 714.7D (mm)
Server weight
Basic Configuration ( excludes keyboard and monitor):
20 kg
Table 17
Environmental Specifications
Item
Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 6.
7
Bels
(operating at room temperature)
LWad:
6.7
Bels
(Idle at room temperature)