HP StorageWorks 1510i HP StorageWorks 1510i Modular Smart Array maintenance an - Page 52
Installing the controller, Verifying proper operation, hot-plugged into a single-controller con
View all HP StorageWorks 1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Installing the controller 1. Insert the new or serviced array controller into the MSA chassis controller bay (1). 2. Push the controller in as far as it will go, making sure that the controller is seated, and then press the latch handle inward until it is flush against the front panel (2). 1 2 15493 3. If necessary, power on the MSA as instructed in Powering on the MSA. NOTE: Each time a system with two controllers is powered on or restarted, or if a second controller is hot-plugged into a single-controller configuration, the firmware versions on the controllers are compared. If the firmware versions on the two controllers are not the same, the controller LCD panel prompts to clone the firmware from the controller with the latest version onto the other controller. For more information, see the MSA1510i installation and user guide. Verifying proper operation After replacing the array controller, controller cache module, or cache module battery pack, verify that: • The controller Heartbeat LED is blinking. • The controller Fault LED is off. • No new error messages are displayed on the array controller LCD display panel. After installing a new array controller, verify that the latest available firmware is installed. For information, see the MSA1510i installation and user guide. newpage pi 52 Customer replaceable components