HP StorageWorks 1510i HP StorageWorks 1510i Modular Smart Array maintenance an - Page 68
Spare Chassis Detected, Chassis Serial Number Flashed Updated, I2c Write Failure, Startup Complete
View all HP StorageWorks 1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
5. Read the controller LCD panel messages during the MSA startup routine. • If the following messages are displayed, the serial number of the original chassis was automatically transferred to the replacement chassis. SPARE CHASSIS DETECTED CHASSIS SERIAL NUMBER FLASHED UPDATED IMPORTANT: If these messages are displayed, the MSA1510i will automatically restart. • If the following message is displayed, it may safely be ignored. I2C WRITE FAILURE • When the following message is displayed, the startup routine is complete. STARTUP COMPLETE Verifying proper operation After replacing the failed chassis, verify that: • No error messages are displayed on the controller LCD panels. • The chassis Power LED is solid green. • The chassis Heartbeat LED is blinking green. • LEDs on each MSA module are showing a healthy status. IMPORTANT: If CHASSIS MISMATCH POWER OFF AND FIX is displayed on the controller LCD panel, persistent data stored on all of the hard drives does not match. The original configuration was changed or startup procedures were followed incorrectly. Power off the MSA1510i, correct any configuration changes, and repeat the power-on sequence. 68 Customer replaceable components