HP StorageWorks 4/256 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-0 - Page 218
EM-1016, EM-1017, EM-1018, EM-1019
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 218 highlights
22 EM-1016 Severity WARNING EM-1016 Message , [EM-1016], ,, WARNING, , Cold recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING EM-1017 Message , [EM-1017], ,, WARNING, , Uncommitted WWN change detected. Cold reboot required. Probable Cause Indicates that a user did not commit a changed world wide name (WWN) value prior to executing a reboot, power cycle, or firmwareDownload operation. Recommended Change and commit the new WWN value. Action Severity WARNING EM-1018 Message , [EM-1018], , FFDC, CRITICAL, , CP blade in slot failed to retrieve current chassis type (//0x). Probable Cause Indicates that there was a failure to read the chassis type from the system. Recommended Verify that the control processor (CP) blade is operational and is properly seated in its slot. Action Severity CRITICAL EM-1019 Message , [EM-1019], ,, WARNING, , Current chassis configuration option () is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync. 148 Fabric OS Message Reference 53-1001338-01