MS-1009, Message, Probable Cause, Recommended, Action, Severity, supportFtp, supportSave
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 508 highlights
69 MS-1009 MS-1009 Message , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Probable Cause Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by the . The following messages will be displayed: • Exceeded bit error rate threshold • Loss of signal or synchronization • Not operational seq. recognized • Primitive sequence timeout • Unrecognized link incident Recommended Action Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages persist. Severity ERROR MS-1021 Message , [MS-1021], ,, ERROR, , MS WARMBOOT failure(FSS_MS_WARMINIT failed. Reason=). Probable Cause Indicates the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT phase of a reboot. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service . Probable Cause Indicates Management Server Platform Service is being activated or deactivated. Recommended No action is required. Action Severity INFO 438 Fabric OS Message Reference 53-1001338-01