HP StorageWorks 4/256 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-0 - Page 680
SWCH-1019, command or
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 680 highlights
97 SWCH-1019 SWCH-1019 Message , [SWCH-1019], ,, INFO, , Device tries to flogi, reject FLOGI as persistent PID is set on device and port has user area bound to it. Probable Cause Indicates a WWN-PID and PortAddress binding collision. Recommended Action The Peristent PID is set on the device and requested area cannot be assigned because it is user bound to a different port. Remove the WWN-PID binding or remove portAddress binding and re-enable the port and then run the wwnaddress --unbind wwn command or the portaddress --unbind slot/port command. Severity INFO SWCH-1020 Message , [SWCH-1020], ,, WARNING, ,HA state out of sync: Standby CP (ver = ) does not support QOS links to AG(Active CP version = ). Probable Cause Indicates the standby control processor (CP) does not support links to AG running QOS. Recommended Load a firmware version on the standby CP that supports QOS links to AG, using the Action firmwareDownload command. Severity WARNING 610 Fabric OS Message Reference 53-1001338-01