95 SSMD-1005 DRAFT: BROCADE CONFIDENTIAL Probable Cause Indicates that the specified function has failed to unlock the mutex (semaphore). Recommended Restart or power cycle the switch. Action Severity ERROR SSMD-1005 Message , [SSMD-1005], ,, ERROR, ,SSM startup failed. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected, severe error during basic startup and initialization. Recommended Action Restart or power cycle the switch .If the condition persists then download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR SSMD-1200 Message , [SSMD-1200], ,, WARNING, ,QoS failed programming ASIC / . Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for the enforcing Multicast Rate Limit feature. Recommended Delete and reapply QoS Multicast Rate Limit policy. Restart or power cycle the switch. Action Severity WARNING SSMD-1201 Message , [SSMD-1201], ,, WARNING, ,QoS failed programming ASIC / Multicast Tail Drop. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for the enforcing Multicast Tail Drop feature. Recommended Delete and reapply QoS Multicast Tail Drop policy. Restart or power cycle the switch. Action Severity WARNING 584 Fabric OS Message Reference 53-1001338-01