DRAFT: BROCADE CONFIDENTIAL ESWCH System Messages Chapter 24 ESW-1001 Message , [ESW-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates that the switch enable has failed. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR ESW-1002 Message , [ESW-1002], ,, INFO, , Security violation: Unauthorized device tries to flogin to port . Probable Cause Indicates that the device is not present in the authorized profile list. Recommended Action Verify that the device is authorized to log in to the switch. If the device is authorized, first run the secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If it is not listed, run the secPolicyAdd command to add this device to an existing policy. Severity INFO ESW-1003 Message , [ESW-1003], ,, ERROR, , Slot ENABLED but Not Ready during recovery, disabling slot = (). Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery. Recommended On a Brocade 8000 switch, restart or power cycle the switch. Action Severity ERROR Fabric OS Message Reference 163 53-1001338-01