HP StorageWorks 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 131
BL-1007, Message, Probable Cause, Recommended, Action, Severity, systemVerification, diagPost
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
BL-1007 7 BL-1007 Message , [BL-1007], ,, WARNING, , blade #: blade state is inconsistent with EM. bl_cflags 0x, slot_on , slot_off , faulty , status . Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control processor (CP). Recommended No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive Action operation and can stop I/O traffic, you might have to stop and restart the traffic during this process. Severity WARNING BL-1008 Message , [BL-1008], , FFDC, CRITICAL, , Slot control-plane failure. Expected value: 0x, Actual: 0x. Probable Cause Indicates that the blade has experienced a hardware failure or was removed without following the recommended removal procedure. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1009 Message , [BL-1009], , FFDC, CRITICAL, , Blade in slot timed out initializing the chips. Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. Fabric OS Message Reference 61 53-1001338-01