HP StorageWorks 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 167
CNM System Messages
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
Chapter CNM System Messages 16 CNM-1001 Message , [CNM-1001], ,, ERROR, , Failed to allocate memory: . Probable Cause Indicates that the specified function failed to allocate memory. Recommended Check memory usage on the switch using the memShow command. Reboot or power cycle the Action switch. Severity ERROR CNM-1002 Message , [CNM-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the CNM has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CNM-1003 Message , [CNM-1003], ,, WARNING, , Crypto device configuration between local switch () and peer () is out of sync. New encryption session is not allowed. Probable Cause Indicates that the encryption engine (EE) nodes in the cluster encryption group have different configurations. Recommended Synchronize the configuration in the cluster group using the cryptodevicecfg command. Refer to the Action Fabric OS Command Reference Manual for more information on this command. Severity WARNING CNM-1004 Message , [CNM-1004], ,, INFO, , iSCSI service is on the switch. Fabric OS Message Reference 97 53-1001338-01