HP StorageWorks 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 346
FW-1004, FW-1005, FW-1006
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 346 highlights
42 FW-1004 Severity WARNING FW-1004 Message , [FW-1004], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a value within the acceptable range. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. If you receive a temperature-related message, check for an accompanying fan-related message and check fan performance. If all fans are functioning normally, check the climate control in your lab. Severity INFO FW-1005 Message , [FW-1005], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Consistently abnormal fan speeds generally indicate that the fan is malfunctioning. Severity INFO FW-1006 Message , [FW-1006], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically contribute to temperature problems. Recommended Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan Action field-replaceable unit (FRU). Severity WARNING 276 Fabric OS Message Reference 53-1001338-01