HP StorageWorks 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 160
CCFG-1005, Probable Cause, Recommended, Action, copy file startup-config, Severity, Message
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
13 CCFG-1005 DRAFT: BROCADE CONFIDENTIAL Probable Cause Indicates that the startup configuration has been moved or deleted, hence replaying the system configuration has failed. Recommended Use the copy file startup-config command to restore the startup configuration from any backup Action retrieved on the server. Severity ERROR CCFG-1005 Message , [CCFG-1005], ,, INFO, , Startup configuration is updated. Probable Cause Indicates that the startup configuration has been updated by the user. Recommended No action is required. Action Severity INFO CCFG-1006 Message , [CCFG-1006], ,, INFO, , Current system running configuration is updated. Probable Cause Indicates that the current running configuration has been updated. Recommended No action is required. Action Severity INFO CCFG-1007 Message , [CCFG-1007], ,, INFO, , startup configuration is erased. Probable Cause Indicates that the startup configuration has been moved or deleted. Recommended No action is required. Action Severity INFO CCFG-1008 Message , [CCFG-1008], ,, ERROR, , CMSH init failed: . 90 Fabric OS Message Reference 53-1001338-01