HP StorageWorks 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 669
SULB-1010, firmwareDownload, Severity, Message, Probable Cause, firmwareCommit, Recommended, Action
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 669 highlights
96 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message , [SULB-1010], , AUDIT, INFO, , Firmwarecommit failed (status=0x). Probable Cause Indicates the firmwareCommit command has failed. The error code provides debugging information. See Table 7 for more information. Recommended If the failure is caused by an inconsistent filesystem, contact your switch service provider. Action Severity INFO SULB-1011 Message , [SULB-1011], ,, INFO, , Firmwaredownload command failed. . Probable Cause Indicates the firmwareDownload command has failed. The additional state code indicates where in the process it failed. Status code provides debugging information (see the tables in message 1109). Recommended Action Run the firmwareDownloadStatus command for more information. Refer to the Troubleshooting section of the Fabric OS Administrator's Guide for additional information. Severity INFO SULB-1017 Message Probable Cause , [SULB-1017], , AUDIT, ERROR, , Firmwaredownload failed in slot . Indicates the firmwareDownload command has failed in the specified blade. The error may be caused by an inconsistent AP blade firmware stored on the active CP. It may also be caused by an internal Ethernet issue or by a persistent storage hardware failure. Fabric OS Message Reference 599 53-1001338-01