Verify New Device Recognition
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Verify New Device Recognition To verify the system recognizes the devices on the newly installed disk array: 1. Power on the system. 2. Log in to the system as root. 3. Generate a file containing peripheral device information by entering hinv -v > /tmp/hinv.info 4. Display peripheral device information by entering more /tmp/hinv.info Example TID=0, LUN = 0, SCSI controller 8 TID=0, LUN = 1, SCSI controller 8 TID=0, LUN = 2, SCSI controller 8 # more /tmp/hinv.info 4 250 MHZ IP27 Processors CPU: MIPS R10000 Processor Chip Revision: 3.4 FPU: MIPS R10010 Floating Point Chip Revision: 0.0 Main memory size: 2048 Mbytes Instruction cache size: 32 Kbytes Data cache size: 32 Kbytes Secondary unified instruction/data cache size: 4 Mbytes Integral SCSI controller 2: Version Fibre Channel AIC-1160, revision 2 Integral SCSI controller 0: Version QL1040B (rev. 2), single ended Disk drive: unit 1 on SCSI controller 0 CDROM: unit 6 on SCSI controller 0 Integral SCSI controller 1: Version QL1040B (rev. 2), single ended Integral SCSI controller 3: Version Fibre Channel AIC-1160, revision 2 Integral SCSI controller 4: Version Fibre Channel AIC-1160, revision 2 Integral SCSI controller 5: Version Fibre Channel AIC-1160, revision 2 Integral SCSI controller 6: Version Fibre Channel AIC-1160, revision 2 Integral SCSI controller 8: Version Fibre Channel QL2200 Disk drive: unit 0 on SCSI controller 8 Disk drive: unit 0, lun 1 on SCSI controller 8 Disk drive: unit 0, lun 2 on SCSI controller 8 Disk drive: unit 0, lun 3 on SCSI controller 8 Disk drive: unit 0, lun 4 on SCSI controller 8 Disk drive: unit 0, lun 5 on SCSI controller 8 Disk drive: unit 0, lun 6 on SCSI controller 8 Disk drive: unit 0, lun 7 on SCSI controller 8 Disk drive: unit 0, lun 8 on SCSI controller 8 Disk drive: unit 0, lun 9 on SCSI controller 8 Disk drive: unit 0, lun 10 on SCSI controller 8 Disk drive: unit 0, lun 11 on SCSI controller 8 Disk drive: unit 0, lun 12 on SCSI controller 8 Disk drive: unit 0, lun 13 on SCSI controller 8 Disk drive: unit 0, lun 14 on SCSI controller 8 Disk drive: unit 0, lun 15 on SCSI controller 8 Integral SCSI controller 7: Version Fibre Channel AIC-1160, revision 2 IOC3 serial port: tty1 IOC3 serial port: tty2 Integral Fast Ethernet: ef0, version 1, module 1, slot io1, pci 2 Origin FIBRE CHANNEL board, module 1 slot 8: Revision 4 SGI IRIX Installation 21
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-sgi-irix-configuration-guide-be2c4aa/21.png)