HP Xw460c HP BladeSystem Onboard Administrator Command Line Interface User Gui - Page 85
Example, SHOW FRU, Service for troubleshooting, repair, and ordering replacements.
View all HP Xw460c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
o Temperature in degrees Celsius for all temperature sensors • Access level/Bay level: All Bay specific • Restrictions: None Example OA-0018FE27577F> SHOW ENCLOSURE TEMP Locale Temp Status Enclosure OK Onboard Administrator 1 OK Blade Bay 7 N/A Blade Bay 8 N/A Blade Bay 2A N/A Blade Bay 2B N/A Interconnect Module 1 OK Temp -------26C/ 78F 26C/ 78F 20C/ 68F 25C/ 77F 25C/ 77F 27C/ 80F Caution ------- 75C 75C 38C 45C 40C 40C Critical -------- 80C 80C 43C 60C 45C 45C SHOW FRU • Command: SHOW FRU • Description: o The FRU Summary section provides information on all field replaceable units within the enclosure. o Information provided in this section can quickly aid the administrator in contacting HP Customer Service for troubleshooting, repair, and ordering replacements. • Access level/Bay level: All Bay specific • Restrictions: You must have access to the specified bay. Example OA-0018FE27577F> show fru Enclosure Model: BladeSystem c3000 Enclosure Manufacturer: HP Serial Number: 0987654321 Part Number: 437506-B21 Enclosure Midplane Manufacturer: HP Spare Part Number: 441829-001 Onboard Administrator 1 Model: BladeSystem c3000 Onboard Administrator Manufacturer: HP Serial Number: P30590A9VUQ04B Enclosure management commands 85