HP Z4 Maintenance and Service Guide - Page 106

Specifications, Rated Input Current

Page 106 highlights

C Specifications Metric U.S. Computer dimensions Width 21.6 cm 8.5 in Depth 55.1 cm 21.7 in Height 44.5 cm 17.5 in Weight 31.7 kg maximum, 22.4 kg minimum, 23.7 kg typical (exact weights depend on configuration) 70.0 lbs maximum, 49.4 lbs minimum, 52.2 lbs typical (exact weights depend on configuration) Temperature Range Operating Nonoperating 5° to 35°C -40° to 60°C 40° to 95°F -40° to 140°F NOTE: The operating temperature is derated 1.0° C per 300 m (1000 ft) when used above 1524m (5000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/hr. The upper limit may be limited by the type and number of options installed. Relative Humidity (noncondensing) Operating Nonoperating (38.7°C max wet bulb) 10-90% 5-95% 10-90% 5-95% Maximum Altitude (unpressurized) Operating (with solid-state drives) Operating (with hard drives) Nonoperating 5,000 m 3,048 m 15,240 m 16,404 ft 10,000 ft 50,000 ft Power Supply 1 Operating voltage range Rated voltage frequency range Operating line frequency range 1125W / 1275W* / 1450W* 90-269 VAC 100-127 VAC @ 50-60 Hz, 200-240 VAC @ 50-60 Hz, 118 VAC @ 400 Hz 100-127 VAC @ 47-66 Hz, 200-240 VAC @ 47-66 Hz, 118 VAC @ 393-407 Hz 12A @ 100-127 VAC, 10A @ 200-240 VAC, 12A @ 118 VAC Standard Efficiency High Efficiency 180 W, 250 W active PFC 1000 W 90% efficiency, custom power supply (wide-ranging, active PFC) Rated Input Current 1000 W 12A @ 100-127 VAC, 6.3A @ 200-240 VAC 12A @ 118 VAC Power Supply 2 1450W / 1550W* / 1700W* 98 Appendix C Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

C
Specifications
Metric
U.S.
Computer dimensions
Width
21.6 cm
8.5 in
Depth
55.1 cm
21.7 in
Height
44.5 cm
17.5 in
Weight
31.7 kg maximum, 22.4 kg
minimum, 23.7 kg typical
(exact weights depend on
configuration)
70.0 lbs maximum, 49.4 lbs
minimum, 52.2 lbs typical
(exact weights depend on
configuration)
Temperature Range
Operating
Nonoperating
5° to 35°C
-40° to 60°C
40° to 95°F
-40° to 140°F
NOTE:
The operating temperature is derated 1.0° C per 300 m (1000 ft) when used above 1524m (5000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating (with solid-state drives)
Operating (with hard drives)
Nonoperating
5,000 m
3,048 m
15,240 m
16,404 ft
10,000 ft
50,000 ft
Power Supply 1
Operating voltage range
Rated voltage frequency range
Operating line frequency range
1125W / 1275W* / 1450W*
90-269 VAC
100-127 VAC @ 50-60 Hz, 200-240 VAC @ 50-60 Hz, 118 VAC @
400 Hz
100-127 VAC @ 47-66 Hz, 200-240 VAC @ 47-66 Hz, 118 VAC @
393-407 Hz
12A @ 100-127 VAC, 10A @ 200-240 VAC, 12A @ 118 VAC
Standard
Efficiency
High
Efficiency
180 W, 250 W active PFC
1000 W 90%
efficiency,
custom power supply (wide-ranging,
active PFC)
Rated Input Current
1000 W
12A @ 100-127 VAC, 6.3A @ 200-240 VAC
12A @ 118 VAC
Power Supply 2
1450W / 1550W* / 1700W*
98
Appendix C
Specifications