HP rp8440 User Service Guide, Sixth Edition - HP Integrity rx8640, HP 9000 rp8 - Page 20

Server Rear View, PCI OLR Fans, PCI I/O Card Core I/O Cards, Rear OLR Fans

Page 20 highlights

The server has the following dimensions: • Depth: Defined by cable management constraints to fit into a standard 36-inch deep rack: 25.5 inches from front rack column to PCI connector surface 26.7 inches from front rack column to core I/O card connector surface 30 inches overall package dimension, including 2.7 inches protruding in front of the front rack columns • Width: 17.5 inches, constrained by EIA standard 19-inch racks • Height: 17 U (29.55 inches), constrained by package density The mass storage section located in the front enables access to removable media drives without removal of the bezel. The mass storage bay accommodates two 5.25-inch removable media drives and up to four 3.5-inch hard disk drives. The front panel display, containing LEDs and the system power switch, is located directly above the hard drive media bays. Below the mass storage section and behind a removable bezel are two PCI-X power supplies. Each PCI-X power supply powers both I/O partitions. Two PCI-X power supplies offer a N+1 configuration. Enclosed with protective finger guards are nine front online replace (OLR) fan modules. The bulk power supply is partitioned by a sealed metallic enclosure located in the bottom of the server. This enclosure houses the N+1 fully redundant bulk power supplies. Install these power supplies from the front of the server after removing the front bezel. The power supply is 2.45 X 5.625 X 20.0 inches. Figure 1-4 Server (Rear View) PCI OLR Fans PCI I/O Card Section Core I/O Cards Rear OLR Fans AC Power Receptacles Access the PCI-X I/O card section, located toward the rear by removing the top cover. 20 HP Integrity rx8640 Server Overview

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197

The server has the following dimensions:
Depth: Defined by cable management constraints to fit into a standard 36-inch deep rack:
25.5 inches from front rack column to PCI connector surface
26.7 inches from front rack column to core I/O card connector surface
30 inches overall package dimension, including 2.7 inches protruding in front of the front
rack columns
Width: 17.5 inches, constrained by EIA standard 19-inch racks
Height: 17 U (29.55 inches), constrained by package density
The mass storage section located in the front enables access to removable media drives without
removal of the bezel. The mass storage bay accommodates two 5.25-inch removable media drives
and up to four 3.5-inch hard disk drives. The front panel display, containing LEDs and the system
power switch, is located directly above the hard drive media bays.
Below the mass storage section and behind a removable bezel are two PCI-X power supplies.
Each PCI-X power supply powers both I/O partitions. Two PCI-X power supplies offer a N+1
configuration.
Enclosed with protective finger guards are nine front online replace (OLR) fan modules.
The bulk power supply is partitioned by a sealed metallic enclosure located in the bottom of the
server. This enclosure houses the N+1 fully redundant bulk power supplies. Install these power
supplies from the front of the server after removing the front bezel. The power supply is 2.45 X
5.625 X 20.0 inches.
Figure 1-4 Server (Rear View)
PCI OLR Fans
PCI I/O Card Section
Core I/O Cards
Rear OLR Fans
AC Power Receptacles
Access the PCI-X I/O card section, located toward the rear by removing the top cover.
20
HP Integrity rx8640 Server Overview