Hitachi 43FDX01B Service Manual - Page 13

EN 13, LGE PDP 2K6 - service mode

Page 13 highlights

Service Modes, Error Codes, and Fault Finding 5.1.1 No Display Check each section with following method. If there is a problem, replace or repair that part. If it is not found, go to the next section. Connectors Check all connectors (PSU, Y-SUS, CTRL, Z-SUS). The module may not function normally by a misconnection (can not send signal and/or power). Also misconnection for a long period can cause a specific board to fail. LGE PDP 2K6 5. EN 13 G_16390_039.eps 110806 Figure 5-3 Control + Y-SUS board G_16390_042.eps 010906 Figure 5-6 Signal input (LVDS) Exhaust Tip Check the Exhaust Tip for cracks with the naked eye to check the vacuum state. If there is a problem, replace the PDP module by a new one. In case of vacuum breakdown, the module makes a shaking noise because of inside gas ventilation. There may be a small crack, which cannot be seen with the naked eye. This noise is different from capacitor noise. G_16390_040.eps 010906 Figure 5-4 Control + Z-SUS board NORMAL F_15590_069.eps 050705 Figure 5-7 Exhaust tip "normal" Figure 5-5 Control + X board G_16390_041.eps 110806

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

Service Modes, Error Codes, and Fault Finding
EN 13
LGE PDP 2K6
5.
5.1.1
No Display
Check each section with following method.
If there is a problem, replace or repair that part.
If it is not found, go to the next section.
Connectors
Check all connectors (PSU, Y-SUS, CTRL, Z-SUS). The
module may not function normally by a misconnection (can not
send signal and/or power). Also misconnection for a long
period can cause a specific board to fail.
Figure 5-3 Control + Y-SUS board
Figure 5-4 Control + Z-SUS board
Figure 5-5 Control + X board
Figure 5-6 Signal input (LVDS)
Exhaust Tip
Check the Exhaust Tip for cracks with the naked eye to check
the vacuum state.
If there is a problem, replace the PDP module by a new one.
In case of vacuum breakdown, the module makes a shaking
noise because of inside gas ventilation.
There may be a small crack, which cannot be seen with the
naked eye. This noise is different from capacitor noise.
Figure 5-7 Exhaust tip "normal"