EN 16 5. LGE PDP 2K6 Service Modes, Error Codes, and Fault Finding Line Open or Short with the Same Distance This is an MCM of Control board defect. The MCM cannot be replaced separately. So replace the Control board. MCM (Multi Chip Module) Disconnected MCM of CTRL board defect. MCM can not be replaced separately. So replace the CTRL board. G_16390_064.eps 180806 Figure 5-15 Evenly repeated lines 5.1.4 Bar Defect (Horizontal) Most horizontal defects can be repaired. In case of adherence between a part of the film and the rear panel electrode, or a panel electrode open/short, replace the PDP panel. Connector If the connectors on the Y board and Z board are not plugged in well, it can result in a horizontal bar, because the sustain voltage cannot be supplied to the panel. So check the FPC connectors and YSUSYDRV first. . Disconnected Screen off F_15590_086.eps 060705 Figure 5-17 Check drive connectors Scan IC Check Check the diode value of the right side part of the output pin. Normal diode value= 0.6 (forward) Normal diode value= OL (reverse) F_15590_087.eps 060705 Figure 5-18 Scan IC output diode check 5.1.5 Line Defect (Horizontal) FPC Check In case of one or more horizontal lines, this is probably due to FPC or panel inside the Control board. Y board is just normal. FPC electrode open Panel electrode Insulation break down Horizontal bar F_15590_085.eps 060705 Figure 5-16 Check FPC connectors Horizontal 1 line. F_15590_089.eps 070705 Figure 5-19 Open FPC electrode / Panel electrode breakdown