Hitachi HTS541680J9SA00 Specifications - Page 129
Set Max Address Ext 37h
View all Hitachi HTS541680J9SA00 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Travelstar 5K160 (SATA) Hard Disk Drive Specification 14.37 Set Max Address Ext (37h) Command Block Output Registers Register 76543210 Data Low -------- Data High -------- Feature Current Previous Sector Count Current B Previous LBA Low Current V V V V V V V V Previous V V V V V V V V LBA Mid Current V V V V V V V V Previous V V V V V V V V LBA High Current V V V V V V V V Previous V V V V V V V V Device -1- - - - - - Command 00110111 Command Block Input Registers Register 76543210 Data Low -------- Data High -------- Error ...See Below... Sector Count LBA Low LBA Mid LBA High Device Status HOB=0 HOB=1 HOB=0 V V V V V V V V HOB=1 V V V V V V V V HOB=0 V V V V V V V V HOB=1 V V V V V V V V HOB=0 V V V V V V V V HOB=1 V V V V V V V V -------...See Below... Error Register 7 65432 1 0 CRC UNC 0 IDN 0 ABT T0N AMN 0 0 0 0 0V 0 0 Figure 77 Set Max Address Ext Command (37h) Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0 - - 0 0V This command is immediately preceded by a Read Native Max Address Ext command. This command overwrites the maximum number of Address of HDD in a range of actual device capacity. Once device receives this command, all accesses beyond that Address are rejected with setting ABORT bit in status register. When the address requested is greater than 268,435,455, words (103:100) shall be modified to reflect the requested value, but words (61:60) shall not modified. When the address requested is equal to or less than 268,435,455, words (103:100) shall be modified to reflect the requested value, and words (61:60) shall also be modified. If this command is not supported, the maximum value to be set exceeds the capacity of the device, a host protected area has been established by a Set Max Address command, the command is not immediately preceded by a Read Native Max Address Ext command, or the device is in the Set Max Locked or Set Max Frozen state, the device shall return command aborted. The device returns the command aborted for a second non-volatile Set Max Address Ext command until next power on. Output Parameters To The Device B LBA Low Current LBA Low Previous LBA Mid Current LBA Mid Previous LBA High Current LBA High Previous Input Parameters From The Device LBA Low (HOB=0) Option bit for selection whether nonvolatile or volatile. B=0 is volatile condition. When B=1, Max Address which is set by Set Max Address Ext command is preserved by POR. When B=0, Max Address which is set by Set Max Address Ext command will be lost by POR. Set Max LBA (7:0). Set Max LBA (31:24). Set Max LBA (15:8). Set Max LBA (39:32). Set Max LBA (23:16). Set Max LBA (47:40). Set Max LBA (7:0). 129/167