Hitachi HTS541680J9SA00 Specifications - Page 91

Idle E3h/97h

Page 91 highlights

Travelstar 5K160 (SATA) Hard Disk Drive Specification 14.9 Idle (E3h/97h) Command Block Output Registers Register 76543210 Data -------- Feature -------- Sector Count VVVVVVVV LBA Low -------- LBA Mid -------- LBA High -------- Device -------- Command 11100011 Command Block Input Registers Register 76543210 Data -------- Error ...See Below... Sector Count -------- LBA Low -------- LBA Mid -------- LBA High -------- Device -------- Status ...See Below... Error Register 7 6 5 4 3 2 1 0 CRC UNC 0 IDN 0 ABT T0N AM N 000 0 0V0 0 Figure 42 Idle Command (E3h/97h) Status Register 7 6543 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0V0V - 0 0V When the power save mode is Standby mode, the Idle command causes the device to enter performance Idle mode immediately, and set auto power down timeout parameter(standby timer). And then the timer starts counting down. When the device's power save mode is already any idle mode, the device keep that mode. When the Idle mode is entered, the device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed. During Idle mode the device is spinning and ready to respond to host commands immediately. Output Parameters To The Device Sector Count Timeout Parameter. If zero, the timeout interval(Standby Timer) is disabled. If other than zero, the timeout interval is set for (Timeout Parameter x5) seconds. The device will enter Standby mode automatically if the timeout interval expires with no device access from the host. The timeout interval will be reinitialized if there is a device access before the timeout interval expires. 91/167

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167

Travelstar 5K160 (SATA) Hard Disk Drive Specification
91/167
14.9
Idle (E3h/97h)
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4
3
2
1
0
Register
7 6 5 4 3 2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
-
-
-
-
-
-
-
-
Error
...See Below...
Sector Count
V V V V V V V V
Sector Count
-
-
-
-
-
-
-
-
LBA Low
-
-
-
-
-
-
-
-
LBA Low
-
-
-
-
-
-
-
-
LBA Mid
-
-
-
-
-
-
-
-
LBA Mid
-
-
-
-
-
-
-
-
LBA High
-
-
-
-
-
-
-
-
LBA High
-
-
-
-
-
-
-
-
Device
-
-
-
-
-
-
-
-
Device
-
-
-
-
-
-
-
-
Command
1 1 1 0
0
0
1
1
Status
...See Below...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC UNC
0
IDN
0
ABT
T0N
AM
N
BSY
RDY
DF
DSC
DRQ COR
IDX
ERR
0
0
0
0
0
V
0
0
0
V
0
V
-
0
0
V
Figure 42 Idle Command (E3h/97h)
When the power save mode is Standby mode, the Idle command causes the device to enter
performance Idle mode immediately, and set auto power down timeout parameter(standby timer).
And then the timer starts counting down. When the device’s power save mode is already any idle
mode, the device keep that mode.
When the Idle mode is entered, the device is spun up to operating speed. If the device is already
spinning, the spin up sequence is not executed.
During Idle mode the device is spinning and ready to respond to host commands immediately.
Output Parameters To The Device
Sector Count
Timeout Parameter. If zero, the timeout interval(Standby Timer) is
disabled. If other than
zero, the timeout interval is set for (Timeout Parameter x5) seconds.
The device will enter Standby mode automatically if the timeout interval expires with no
device access from the host. The timeout interval will be reinitialized if there is a device
access before the timeout interval expires.