IBM 865511Y Hardware Maintenance Manual - Page 175
Diagnostic Error Code, FRU/Action
![]() |
UPC - 087944509769
View all IBM 865511Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 175 highlights
Diagnostic Error Code 000-198-XXX BIOS test aborted 000-199-XXX BIOS test failed, cause unknown 000-250-XXX BIOS APM failure 000-270-XXX BIOS ACPI failure 001-000-XXX System Test Passed 001-00X-XXX System Error 001-01X-XXX System Error 001-024-XXX System Addressing test failure 001-025-XXX System Checksum Value error 001-026-XXX System FLASH data error 001-027-XXX System Configuration/Setup error 001-032-XXX System Device Controller failure 001-034-XXX System Device Buffer Allocation failure 001-035-XXX System Device Reset condition detected 001-036-XXX System Register error 001-038-XXX System Extension failure FRU/Action 1. If a component is called out, make sure it is enabled and/or connected 2. Flash the system and re-test 3. Go to "Undetermined problem" on page 189 1. Go to "Undetermined problem" on page 189. 2. Flash the system and re-test 3. Replace component under function test. 1. Flash the system 2. System board 1. Flash the system 2. System board 1. No action 1. System board 1. System board 1. System board 1. Flash the system 2. System board 1. Flash the system 2. System board 1. Run Setup 2. Flash the system 3. System board 1. System board 1. Reboot the system 2. Flash the system 3. Run memory test 4. System board 1. System board 1. System board 1. Adapter card 2. System board Netfinity 8655 - Type 8655 167