IBM 866631Y Hardware Maintenance Manual

IBM 866631Y - Netfinity 7100 - 8666 Manual

IBM 866631Y manual content summary:

  • IBM 866631Y | Hardware Maintenance Manual - Page 1
    Hardware Maintenance Manual Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 2
  • IBM 866631Y | Hardware Maintenance Manual - Page 3
    Hardware Maintenance Manual Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 4
    Note Before using this information and the product it supports, be sure to read the general information under " . This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other
  • IBM 866631Y | Hardware Maintenance Manual - Page 5
    7100 - Type 8666, Models 1RY, 2RY, 11Y, 21Y. Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Important safety information Be sure to read all caution and danger statements in this book before performing any of the instructions. Leia todas as
  • IBM 866631Y | Hardware Maintenance Manual - Page 6
    /files.html IBM online addresses The HMM manuals online address is: http://www.us.pc.ibm.com/cdt/hmm.html The IBM PC Company Support Page is: http://www.us.pc.ibm.com/support/index.html The IBM PC Company Home Page is: http://www.pc.ibm.com iv Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 7
    Contents About this manual iii Important safety information iii Online support iv IBM online addresses iv General checkout 1 General information 3 Features and specifications 3 Server features 5 Reliability, availability, and serviceability . . . . . 6 Controls and indicators 7 Information
  • IBM 866631Y | Hardware Maintenance Manual - Page 8
    problems 142 Parts listing (Type 8666 145 Part A 145 System 146 Part B 147 System 148 Keyboards 149 Power cords 150 Related service information . . . . . 151 Safety information 152 General safety 152 Electrical safety 152 vi Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 9
    Safety inspection guide 154 Handling electrostatic discharge-sensitive devices 155 Grounding requirements 155 Safety notices (multi-lingual translations) . . . 155 Send us your comments 184 Problem determination tips 185 Notices 185 Trademarks 186 Contents vii
  • IBM 866631Y | Hardware Maintenance Manual - Page 10
    viii Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 11
    you cannot determine whether a problem is caused by the hardware diagnostic programs, a single problem might cause several error computer hangs and no error is displayed, go to "Undetermined problems" on page 142. 5. Power supply problems page 152. 7. For intermittent problems, check the error log;
  • IBM 866631Y | Hardware Maintenance Manual - Page 12
    -on all external devices. v Power-on the computer. v Record any POST error messages displayed on following responses: a. One beep. b. Readable instructions or the Main Menu. 3. DID YOU RECEIVE problem, see "Undetermined problems" on page 142. 2 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 13
    the system hardware to meet your needs today, while providing flexible expansion capabilities for the future. The IBM Netfinity 7100 server comes with a three-year limited warranty and 90-Day IBM Start Up Support. If you have access to the World Wide Web, you can obtain up-to-date information about
  • IBM 866631Y | Hardware Maintenance Manual - Page 14
    : 137 V ac - Input voltage high range: - Minimum: 180 V ac - Maximum: 265 V ac - Input kilovolt-amperes (kVA) approximately: - Minimum: 0.08 kVA - Maximum: 0.52 kVA 4 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 15
    referred to as the service processor. v Integrated network environment support The server comes with a redundant Ethernet connection. If a problem occurs with the primary Ethernet connection, data loss and without user intervention. v IBM ServerGuide CDs The ServerGuide CDs included with the
  • IBM 866631Y | Hardware Maintenance Manual - Page 16
    server design are reliability, availability, and serviceability (RAS). These factors help to ensure Analysis™ (PFA) alerts v Remote system problem-determination support v Power and temperature monitoring v Power-supply diagnostic LED panels 6 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 17
    accessed. Reset button:Press this button to reset the server and run the power-on self-test (POST). Power control button:Press this button to manually turn on or off the server. General information 7
  • IBM 866631Y | Hardware Maintenance Manual - Page 18
    the Power Control button starts an orderly shutdown of the operating system, if this feature is supported by your operating system, and places the server in standby mode. Note: After turning off operator information panel to stop blinking. 8 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 19
    diagnostic panel may also be on. The event is recorded in the Event log. See "Choices available from the Configuration/Setup main menu" on page 31 for information on viewing the Event log. System error light: This amber light is on when a system error occurs. A light on the diagnostics LED panel
  • IBM 866631Y | Hardware Maintenance Manual - Page 20
    lights are on when there is microprocessor activity. The number of lights that are on indicates the number of microprocessors with activity. 10 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 21
    POST beep codes 12 POST error messages 12 Event/error logs 12 Small computer system interface messages . . . . 12 Diagnostic programs and error 22 Troubleshooting the Ethernet controller . . . . 23 Network connection problems 23 Ethernet controller troubleshooting Copyright IBM Corp. 1999 11
  • IBM 866631Y | Hardware Maintenance Manual - Page 22
    is illuminated on the operator information panel. If POST detects a problem, more than one beep sounds and an error message appears on ; then, select Event/Error Logsfrom the main menu. Small computer system interface messages If you receive a SCSI error message, Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 23
    ; they are not intended to be used to identify a failing part. Troubleshooting and servicing of complex problems that are indicated by error messages should be performed by trained service personnel. Sometimes the first error to occur causes additional errors. In this case, the server displays
  • IBM 866631Y | Hardware Maintenance Manual - Page 24
    ; then, follow the instructions on the screen. Notes problem persists during normal server operations, a software error might be the cause. If you suspect a software problem, refer to the information that comes with the software package. 14 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 25
    screen. 4. Select View Test Log from the list that appears; then, follow the instructions on the screen. The system maintains the test-log data while the server is . Light path diagnostics The server has LEDs to help you identify problems with some server components. These LEDs are part of the light
  • IBM 866631Y | Hardware Maintenance Manual - Page 26
    Description and action The power supply is on and operating correctly. There is a dc power problem. Possible causes: 1. The server is not turned on (the power LED is blinking on page 17 for information on identifying problems using these 16 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 27
    . This feature helps you to isolate the problem if an error causes the server to shut problems. See "Choices available from the logged; or a failure occurred Configuration/Setup main menu" on page 31 not on, restart the server. If the problem persists, try to determine the failing adapter by removing
  • IBM 866631Y | Hardware Maintenance Manual - Page 28
    error. 1. Check the error log for additional information. 2. If you cannot correct the problem from the information in the error log, try to determine the failing adapter by removing one server. 3. If the problem persists, replace the VRM. 18 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 29
    distribution busses. Usually a short circuit will cause the power subsystem to shut down because of an overcurrent condition. A general procedure for troubleshooting power problems is as follows: 1. Power off the system and disconnect the AC cord(s). 2. Check for loose cables in the power subsystem
  • IBM 866631Y | Hardware Maintenance Manual - Page 30
    v Cables for optional adapters are routed according to the instructions provided with the adapters (ensure that cables are not the World Wide Web. Go to http://www.pc.ibm.com/support/, select IBM Server Support, and make the selections for the server. The flash Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 31
    must be handled correctly to avoid possible danger. If you replace the battery, you must adhere to the following instructions. CAUTION: When replacing the battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing
  • IBM 866631Y | Hardware Maintenance Manual - Page 32
    that you removed. 10. Insert the plastic dividers into the divider guides. 11. Reinstall the top cover. Note: You must wait 31. Diagnosing errors To find solutions to problems that have definite symptoms, see "Error symptoms" on page 130. 22 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 33
    or new device. Troubleshooting the Ethernet controller This section provides troubleshooting information for problems that might occur X port. v Determine if the hub supports auto-negotiation. If not, try configuring the integrated Ethernet controller manually to match the speed and duplex mode of
  • IBM 866631Y | Hardware Maintenance Manual - Page 34
    2. Ethernet troubleshooting chart Ethernet controller problem Suggested Action The support auto-negotiation, manually configure the Ethernet controller to match the hub. v If you manually configured the duplex mode, make sure that you also manually Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 35
    Table 2. Ethernet troubleshooting chart (continued) Ethernet controller problem Suggested Action The Ethernet controller stopped working This new adapter could not be found. Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant Adapter and make sure that the adapter is seated
  • IBM 866631Y | Hardware Maintenance Manual - Page 36
    Link Interface Driver (MLID) cannot be registered with the Link Support Layer (LSL). Explanation: An error occurred while the driver was trying correctly. Action: Restart the server. If the problem persists, call for service. PCNTNW-NW-086 The driver parameter block is Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 37
    found. Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action:Verify that the Ethernet controller is enabled. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-180 The DMA parameter is not necessary
  • IBM 866631Y | Hardware Maintenance Manual - Page 38
    error messages for the SCO UNIX LLI driver, and suggested actions to resolve each problem. Table 5. UNIX LLI driver messages for the Ethernet controller pnt0-2 PCI search specified the server. Action:Modify the hardware settings. 28 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 39
    Solaris driver has been reset due to a device fault. Action:Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs. IRQ found for PCnet hardware does not match space
  • IBM 866631Y | Hardware Maintenance Manual - Page 40
    number is not necessary for PCI device. pnt0-29 Explanation:The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA the DMA parameter. The IRQ number is already in use. pnt0-31 Explanation:The specified I/O address is already in use. Action:Run Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 41
    software setup and installation tools specifically designed for IBM Netfinity servers. You can use these CDs program This section provides the instructions needed to start the Configuration/ full Configuration/Setup menu. 3. Follow the instructions that appear on the screen. Choices available from
  • IBM 866631Y | Hardware Maintenance Manual - Page 42
    following: IBM Netfinity Setup - © IBM Corporation 1998 Configuration/Setup Utility • System Summary • System Information • Devices and from the system time that is sent to the service processor (Advanced System Management Processor) each 32 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 43
    time the server is started. Use the number keys to enter the hours and minutes and + or − to add or subtract from the system time. If you want the system clock time to be the same as the Advanced System Management Processor clock time, leave the value set at its default of 0. v System Security
  • IBM 866631Y | Hardware Maintenance Manual - Page 44
    the instructions on problem is corrected. Select Memory Settings from the Advanced Setup menu, use the arrow keys to highlight the bank that you want to enable; then, use the arrow keys to select Enable. v System Service Processor Settings 34 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 45
    Select this choice to enable or disable power supply redundancy monitoring. v Event/Error Logs Select this choice to view or clear error logs. - Select Clear error logs to clear the error or event log. - Select POST Error Log to view the three most recent error codes and messages that the system
  • IBM 866631Y | Hardware Maintenance Manual - Page 46
    v Perform a low-level format on a SCSI hard disk The following sections provide the instructions needed to start the SCSISelect Utility and descriptions of the menu choices available. Note: If the utility program: 1. Turn on the server. 36 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 47
    the SCSI controller to its default values, press F6; then, follow the instructions that appear on the screen. You can view or change the following controller configuration options. These options include enabling support for large hard disk drives and support for drives with UltraSCSI speeds. v
  • IBM 866631Y | Hardware Maintenance Manual - Page 48
    , follow the instructions on the screen. Note: Hard disks normally contain more tracks than their stated capacity (to allow for defective tracks). A message appears on the screen if the defect limit is reached. If this happens, replace the hard disk drive. 38 Hardware Maintenance Manual: Netfinity
  • IBM 866631Y | Hardware Maintenance Manual - Page 49
    Installing options This chapter provides instructions to help you add while the system is running, provided that your system is configured to support this function. For complete information about installing or removing a hot-swap Panel Fan assembly Power supply © Copyright IBM Corp. 1999 39
  • IBM 866631Y | Hardware Maintenance Manual - Page 50
    , and memory board component locations. I/O board component locations The following illustration shows the location of the input/output (I/O) connectors on the I/O board. 40 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 51
    Note: The illustrations in this document might differ slightly from your hardware. Power backplane Processor board Keyboard Mouse Video port USB 1 and USB 2 port Ethernet port Management Serial Serial port port A port B ASM Parallel port interconnect SCSI external Processor board component
  • IBM 866631Y | Hardware Maintenance Manual - Page 52
    ) Memory board Connector Battery Jumper block (J10-J16) Flash ROM pageswap jumper block (J56) Power-on password override jumper block (J48) Battery 42 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 53
    Microprocessor core-frequency selection jumper block (J13-J16) Reserved (J10) Reserved (J12) Reserved (J11) Memory board component locations The illustrations in this section show certain locations on the memory board. Memory board connectors The following illustration shows the location of the
  • IBM 866631Y | Hardware Maintenance Manual - Page 54
    , provided that the system is configured to support this function. v The blue color on components options for the Netfinity 7100, refer to http://www.ibm.com/pc/us/compat on the World Wide Web. In this case, follow the instructions in the RAID adapter documentation Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 55
    Removing the top cover Note: The illustrations in this document might differ slightly from your hardware. Top cover Captive screws To remove the server top cover: 1. Loosen the two thumbscrews on the back edge of the top cover. 2. Slide the top cover slightly toward the rear of the server. Lift the
  • IBM 866631Y | Hardware Maintenance Manual - Page 56
    in an expansion slot. When you install a PCI video adapter, the server BIOS automatically disables the integrated video controller. Note: Video adapters are supported in all six PCI slots. The following illustration shows the location of the 64-bit PCI expansion slots on the processor board. 46
  • IBM 866631Y | Hardware Maintenance Manual - Page 57
    jumper settings on the adapter, follow the instructions that come with the adapter documentation. v Slots 3 through 6 support 5.0 V and universal PCI adapters. Note: A Universal PCI adapter supports both 3.3 V and 5.0 V operation. v Slots 1 and 2 support 3.3 V and universal PCI adapters only. v The
  • IBM 866631Y | Hardware Maintenance Manual - Page 58
    characteristics of the system and ensures proper cooling of system components. 5. Refer to the documentation that comes with your adapter for any cabling instructions. It might be easier for you to route any cables before you install the adapter. Refer to "Cabling example for the ServeRAID adapter
  • IBM 866631Y | Hardware Maintenance Manual - Page 59
    seated in the processor-board connector. Incomplete insertion might cause damage to the processor board or the adapter. 10. Lower the tab on the adapter guide over the tab on the top corner of the adapter. Rotate the adapter retention latch clockwise until it snaps into place. 11. Lower the rear
  • IBM 866631Y | Hardware Maintenance Manual - Page 60
    be replaced. When the hard-disk status light indicates a drive fault, you can replace a hot-swap drive without turning off the server. 50 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 61
    inch, 1.44 MB diskette drive. v The left front bays support 5.25-inch, half-high, removable-media drives. Any two drives have a special interface called small computer system interface, or SCSI. Using the instructions in "Connecting external options" on page 65, in addition to the instructions in
  • IBM 866631Y | Hardware Maintenance Manual - Page 62
    the tray handle is open (that is, perpendicular to the drive). c. Align the drive assembly with the guide rails in the bay. d. Gently push the drive assembly into the bay until the drive stops. e. Push hard disk drive is operating properly. 52 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 63
    with a tape drive Filler panel with EMI sheild Slide rails Drive Choose the bay in which you want to install the drive. Also, check the instructions that come with the drive to see if you need to set any switches or jumpers on the drive. To install a removable-media drive in
  • IBM 866631Y | Hardware Maintenance Manual - Page 64
    the tape drive. 7. Align the slide rails on the drive with the guide rails in the bay; then, slide the drive into the bay until the SCSI cable from the hard disk drive backplane, the server will not support a drive in a hot-swap bay. You can obtain an optional SCSI Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 65
    MHz, 72-bit, registered, synchronous, error correcting code (ECC), SDRAM configuration DIMM memory is supported for the 64 MB, 128 MB, 256 MB, 512 MB and 1 GB (when available Refer to "Using the Configuration/Setup Utility program" on page 31 for more information. v Install the DIMMs in the order
  • IBM 866631Y | Hardware Maintenance Manual - Page 66
    , remove the DIMM from the package. Note: To avoid breaking the retaining clips or damaging the DIMM connectors, handle the clips gently. 56 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 67
    /output system (BIOS) code. The latest level of BIOS code for the server is available through the World Wide Web. Go to http://www.pc.ibm.com/support/, select IBM Servers, and make the selections for your server. 2. Obtain an SMP-capable operating system (optional). For a list of
  • IBM 866631Y | Hardware Maintenance Manual - Page 68
    (P4) J37 (VRM J38 (VRM J39 (VRM J41 (VRM 4) 1) 2) 3) X X X X X X X X To install an additional microprocessor kit: 1. Review "Before you begin" on page 43. 58 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 69
    2. Turn off the server and all attached devices. Disconnect all external cables and power cords and remove the top cover. Pop rivets Processor housing cover VRM Terminator card 3. Pull up the two pop rivets on the processor housing cover and remove the cover from the processor housing. 4. Determine
  • IBM 866631Y | Hardware Maintenance Manual - Page 70
    this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Before you continue with the . v Read the documentation that comes with the option. 60 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 71
    Refer to the following illustration to install a hot-swap power supply. Handle DC power light AC power light Filler panel To install an additional power supply: 1. Review "Before you begin" on page 43. 2. Remove the filler panel. 3. Place the handle on the power supply in the open position.
  • IBM 866631Y | Hardware Maintenance Manual - Page 72
    door, reinstall the top cover, and reconnect all the cables that you disconnected, and for certain options, run the Configuration/Setup Utility program. Follow the instructions in this section. 62 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 73
    Attention: For proper cooling and airflow, install the top cover before turning on the server. Operating the server for extended periods of time (over 30 minutes) with the top cover removed might damage server components. Installing the server front door and media-bay bezel Refer to the following
  • IBM 866631Y | Hardware Maintenance Manual - Page 74
    save the new configuration information. See "Configuring the server" on page 31. Some options have device drivers that you need to install. Refer microprocessor, you might want to upgrade the operating system to support symmetric multiprocessing (SMP). Run the Configuration/Setup Utility program to
  • IBM 866631Y | Hardware Maintenance Manual - Page 75
    : 1. Turn off the server and all attached devices. 2. Follow the instructions that come with the option to prepare it for installation and to connect it Parallel port The server has one parallel port. This port supports three standard Institute of Electrical and Electronics Engineers (IEEE) 1284
  • IBM 866631Y | Hardware Maintenance Manual - Page 76
    data can be both read from and written to a device. In bidirectional mode, the server supports the ECP and EPP modes. To view or change the parallel-port assignment: 1. Restart the feed) -AUTO FD 15 I -ERROR -ERROR 16 O -INIT -INIT 66 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 77
    Table 10. Parallel-port connector pin-number assignments (continued) Pin I/O SPP/ECP Signal EPP Signal 17 O -SLCT IN -SLCT IN 18 - Ground Ground 19 - Ground Ground 20 - Ground Ground 21 - Ground Ground 22 - Ground Ground 23 - Ground Ground 24 - Ground Ground 25 - Ground
  • IBM 866631Y | Hardware Maintenance Manual - Page 78
    2 Not connected 3 Ground 4 +5 V dc 5 Clock 6 Not connected Ultra2 SCSI ports The server has a dual-channel Ultra-2 small computer system interface (SCSI) controller on the I/O board. This controller supports two independent SCSI 68 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 79
    . Each channel supports up to 15 for use with external devices, contact your IBM reseller or IBM marketing representative. For information about the maximum length Refer to the information that is provided with the device for instructions to set its SCSI ID. SCSI connector pin-number assignments
  • IBM 866631Y | Hardware Maintenance Manual - Page 80
    61 -Select 28 +Control/Data 62 -Control/Data 29 +Request 63 -Request 30 +Input/Output 64 -Input/Output 31 +Data 8 65 -Data 8 32 +Data 9 66 -Data9 33 +Data 10 67 -Data 10 34 +Data Devices and I/O Ports; then, press Enter. 70 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 81
    emulates a mouse and you will not be able to disable the mouse settings in the Configuration/Setup Utility program. 3. Check to make sure your NOS supports USB devices. USB cables and hubs You need a 4-pin cable to connect devices to USB 1 or USB 2. If you plan to attach more than two
  • IBM 866631Y | Hardware Maintenance Manual - Page 82
    (100BASE-TX), half duplex (HDX), or full duplex (FDX). The controller supports half-duplex (HDX) and full-duplex (FDX) modes at both speeds. on the ServerGuide CDs. Failover for redundant Ethernet The IBM Netfinity 10/100 Fault Tolerant Adapter is an optional Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 83
    feature currently is supported by Windows NT Server and IntraNetWare. The setup required for each operating system follows. Windows NT Server: To install the IBM Netfinity 10/100 Fault Tolerant Adapter device drivers: 1. Add the redundant NIC adapter according to the instructions that are provided
  • IBM 866631Y | Hardware Maintenance Manual - Page 84
    server Refer to the following illustration for the location of input and output connectors and for an example of proper cable routing. 74 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 85
    Installing the server in a rack Refer to the Rack Installation Instructions for complete rack installation and removal instructions. Installing options 75
  • IBM 866631Y | Hardware Maintenance Manual - Page 86
    76 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 87
    Manager Managing your IBM Netfinity server with Manager installation program 81 Netfinity Manager database support 87 DB2 database support 87 System requirements 87 Installing and configuring Client Services for Netfinity Manager, see the Client Services for Netfinity Manager User 's Guide
  • IBM 866631Y | Hardware Maintenance Manual - Page 88
    and Client Services for Netfinity Manager licenses are available for purchase from your IBM representative. minimum system requirements for Netfinity Manager vary based on which supported operating system is running on your system. v If you 78 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 89
    adapter card and one or more of the following communications protocols: - IBM TCP/IP for OS/2 version 1.2 or later (required for Netfinity Manager any of the other supported SNA stacks. v A 9600 baud or greater modem (optional). The hard disk requirement for Client Services for Netfinity Manager is
  • IBM 866631Y | Hardware Maintenance Manual - Page 90
    Manager systems using any of the other supported SNA stacks. v A 9600 baud or greater modem (optional). The hard disk requirement for Client Services for Netfinity Manager is 6.5 MB-9 MB have administrator-level access to the system. 80 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 91
    Start the computer with your operating system. 2. Place the ServerGuide Netfinity Applications CD into the CD-ROM drive. 3. Follow the instructions for your then refer to the Client Services for Netfinity Manager User's Guide for additional installation instructions. e. Click Install Product to
  • IBM 866631Y | Hardware Maintenance Manual - Page 92
    Support Click Advanced System Management Support to install the Advanced System Management service on this system. Use this service to monitor and manage IBM v Capacity Manager Click Capacity Management to install the Capacity Management service on this system. Capacity Management is an easy to use
  • IBM 866631Y | Hardware Maintenance Manual - Page 93
    screen display of remote systems that are running Netfinity Manager or Client Services for Netfinity Manager. v Update Connector Manager (NT 4.0, TCP/ system updates on client systems using updates that are available from the IBM selection server. v World Wide Web Enhancement (TCP/IP Required) Click
  • IBM 866631Y | Hardware Maintenance Manual - Page 94
    service will be installed only if the required hardware or system configuration is present. 9. Configure the Network Drivers. If the installation configuration allows for network access, enter information regarding the communication protocols that are supported Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 95
    by a remote user. The alert includes the name of the service that was run and information about the user that started the service. v Show Network Support If the Show Network Support option is enabled, the Netfinity Manager Support Program (or Network Interface) will be visible as a minimized process
  • IBM 866631Y | Hardware Maintenance Manual - Page 96
    is enabled and a remote user attempts to use one of these services on your system, a window will pop up on your desktop alerting , Domain Name Server (DNS) address (for example, your.system.ibm.com). Select this option if you are using Netfinity Manager is Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 97
    support" on page 93. DB2 database support Support for DB2 database export is automatically configured during installation of the Netfinity Manager. However, the database system itself must be configured. Instructions DB2 Installation Guide for general requirements and supported protocols. Installing
  • IBM 866631Y | Hardware Maintenance Manual - Page 98
    the database is created 3. Press Enter. 4. Next, you must configure the tables for ODBC database support so the tables can be configured. For information on configuring the database for ODBC, refer to "ODBC for Windows NT has been installed: 88 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 99
    name of the table as specified during database installation. A listing of the Netfinity database table names can be found in the Netfinity User's Guide (Appendix H: Netfinity Relational Database Tables). Note: The Netfinity Database Administration Tool can also be used to GRANT or REVOKE privileges
  • IBM 866631Y | Hardware Maintenance Manual - Page 100
    Manager to discontinue export data through ODBC for use on DB2, refer to "ODBC database support" on page 93. Cataloging the database in the managing system: If the manager is using to delete the database for all supported operating systems. 90 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 101
    For information on what versions of Lotus Notes and the Lotus Notes client are supported, see Table 18 on page 96. See the Notes Administrator's Guide for general system requirements and supported communications protocols. Installing the database To enable Netfinity Manager to export system data to
  • IBM 866631Y | Hardware Maintenance Manual - Page 102
    in the Lotus Notes Workspace. 2. Select from the View pull-down menu the section of the Netfinity Manager database to be browsed. 92 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 103
    contain data gathered by specific Netfinity Manager services. Click the name of the service that gathers the data to be viewed using the Visigenic driver provided with Microsoft SQL Server) or - IBM DB2 For detailed information about supported ODBC platforms, see Table 18 on page 96 and Table 19
  • IBM 866631Y | Hardware Maintenance Manual - Page 104
    . The Netfinity Manager Database Administration service is found in the Netfinity Manager folder or Netfinity Manager program group. Double-click this icon to open the Netfinity Manager Database Administration window. 2. Select a DBMS. 94 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 105
    Click in the Select DBMS listing the name of the DBMS which Netfinity Manager will be using to export data. 3. To create the Netfinity Manager table groups within the database, click Create and then click OK to open the Database Server window. The following table actions are also available: v Delete
  • IBM 866631Y | Hardware Maintenance Manual - Page 106
    release of Netfinity Manager. Table 18. Supported Netfinity Databases for Windows.. Reference by IBM DB2 Version 2.1.2 Yes Yes IBM DB2 Universal Database 5.0 Yes Yes ODBC - IBM DB2 Version 2.1.2 Yes, DB2 Driver Yes, DB2 Driver 96 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 107
    Supported Netfinity Databases for OS/2. (continued). Reference by operating system and database client version. Product OS/2 Warp Connect OS/2 Warp 4.0 ODBC - IBM Manager folder or program group contains the Netfinity Manager Service Manager object. Notes: a. In your Netfinity Manager folder
  • IBM 866631Y | Hardware Maintenance Manual - Page 108
    Management (available only on systems running Windows NT 4.0 or later) v Cluster Manager (available only on systems running Windows NT 4.0 or later) v DMI Browser (requires DMI Service Layer) v ECC Memory Setup (requires ECC memory) 98 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 109
    Manager services follow. Complete instructions on how to use each of these services can be found in the service-specific chapters of the Netfinity Manager User's Guide. Advanced System Management The Advanced System Management service provides extensive functionality available for your IBM PC
  • IBM 866631Y | Hardware Maintenance Manual - Page 110
    system has start-up problems, enabling you to react quickly to problems and minimize downtime. Predictive Failure Analysis The Predictive Failure Analysis (PFA) service enables continual monitoring and system RAID array and RAID adapter, 100 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 111
    (or remove) logical drives, perform data integrity tests, and many other RAID system tasks. This service is available for both stand alone and network use by any system that has a supported RAID adapter. Remote Session Use Remote Session to establish a fully active command session with any remote
  • IBM 866631Y | Hardware Maintenance Manual - Page 112
    of diagnostic tasks on systems that support ROM-based diagnostics. The results to help diagnose and resolve system problems. System Information Tool The System computer; however, the most detail is provided when this service is used with IBM computers. This service Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 113
    systems that are running OS/2. Getting more information about Netfinity Manager Complete information on how to use Netfinity Manager (as well as Client Services for Netfinity Manager) is included in Adobe Acrobat format on the Netfinity Manager CD. Filename DOCSREAD.ME README.SCO NFMGRQB.PDF The
  • IBM 866631Y | Hardware Maintenance Manual - Page 114
    Services for Netfinity Manager User's Guide Client Services for Netfinity Manager for NetWare User's Guide Advanced System Management Information Client Services for Netfinity Manager for SCO UnixWare User's Guide IBM Network Transport Services Client Services for Client Services for Services Services
  • IBM 866631Y | Hardware Maintenance Manual - Page 115
    Manager for OS/2, copy all of the files from the OS2/SERVICES directory into the source directory. 3. Copy the files from the installation program command-line parameters. The Netfinity Manager installation program supports the following command-line parameters: /R: drive+path+filename Specifies
  • IBM 866631Y | Hardware Maintenance Manual - Page 116
    For example: ;IBM SysMgt Install Script, Version 2 (Do not remove this comment line) Netfinity Manager Installation [Manager 16900] Advanced System Management Support [ServProc 450] Option Name. This is used only for identification. 106 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 117
    most cases, it should be the reserved string "NULL." The easiest way to customize an installation is to simply put a semicolon in front of any service that you want to remove from the installation. To add a line item in a specific section, add all the necessary item information in the format shown
  • IBM 866631Y | Hardware Maintenance Manual - Page 118
    108 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 119
    only) Field Replacement Units (FRUs) should be replaced by qualified service personnel only. Diagnostic switch card Use the following illustration when replacing the diagnostic switch card and reattach the front LED card cable and the diagnostic switch card cable. © Copyright IBM Corp. 1999 109
  • IBM 866631Y | Hardware Maintenance Manual - Page 120
    the chassis. 7. Slide the shuttle toward the rear of the server. 8. To remove the shuttle, see "Removing the shuttle" on page 116. 110 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 121
    the cable to the diagnostic switch card. 5. Remove the two retaining screws that secure the board in place. 6. Remove and replace the board. FRU information (service only) 111
  • IBM 866631Y | Hardware Maintenance Manual - Page 122
    level BIOS. Match the BIOS level currently installed on the system. Use the following illustration as a guide to removing the I/O Legacy board. Touchpoints 1. Power-off the server off, if it is on. . v Review "Before you begin" on page 43. 112 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 123
    the memory card assembly into the connector. 6. Install the processor housing cover and push the two pop rivets down to secure the cover. FRU information (service only) 113
  • IBM 866631Y | Hardware Maintenance Manual - Page 124
    with the notches on the floor of the server. Processor/PCI backplane Review the information in "Before you begin" on page 43. 114 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 125
    shuttle. Note: Lift the assembly at an angle for easier removal. 14. To install the new Processor/PCI board, reverse the above procedure. FRU information (service only) 115
  • IBM 866631Y | Hardware Maintenance Manual - Page 126
    power might result in damage to the hardware unless you disconnect the power cord for each power source from the electrical outlet. 116 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 127
    lift the SCSI backplane assembly with backerplate up and out of the server. 8. To install the SCSI backplane assembly, reverse the above procedure. FRU information (service only) 117
  • IBM 866631Y | Hardware Maintenance Manual - Page 128
    118 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 129
    each press. Once the configuration has reset to the default, it must be saved in Setup to be stored in CMOS. 3. For IBM devices not supported by index, refer to the manual for that device. 4. Always start with "General checkout" on page 1. The Symptom-to-FRU lists symptoms, errors, and the possible
  • IBM 866631Y | Hardware Maintenance Manual - Page 130
    video ROM failed) 2-4-1(Video failed, screen believed operable) 1. I/O Legacy board 3-1-1(Timer tick interrupt failed) 1. I/O Legacy Board 3-1-2(Interval timer 1. I/O Legacy Board channel 2 failed) 120 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 131
    modules, then power-on the system operational (see"Using the Configuration/Setup Utility program" on memory in system) page 31). 2. If problem persists, restart the system 3 times. Note: Restarting the system three times will load default settings. 3. DIMMs 4. Memory Board 5. Processor
  • IBM 866631Y | Hardware Maintenance Manual - Page 132
    if one is defective.) 3. Power Backplane No beep and no video 1. See "Undetermined problems" on page 142 System will not 1. See"Power supply LED errors" on page 131 panel LEDs followed by the FRU/Action for correcting the problem. Note: If a diagnostic panel LED is on and the information LED panel
  • IBM 866631Y | Hardware Maintenance Manual - Page 133
    down. Diagnostic Panel LED FRU/Action All LEDs off (Check System Error Log for error condition, then clear System Error Log when the problem is found.) 1. System Error Log is 75% full; clear the log. 2. Bad, missing or mis-installed processor terminator; remove and reinsert terminator. 3. PFA
  • IBM 866631Y | Hardware Maintenance Manual - Page 134
    X (where X is CPU 1, 2, 3, or 4) (CPU LED also on) 1) CPU X 2) Processor/PCI Board e. I/O Legacy Board over recommended temperature 1) Processor/PCI Board 2) I/O Legacy Board 124 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 135
    Diagnostic error codes Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are: 000 The test passed. 195 The Esc key was pressed to abort the test. 197 This is a warning error and may not indicate a hardware failure. For all
  • IBM 866631Y | Hardware Maintenance Manual - Page 136
    Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. SCSI Backplane 4. Adapter 075-XXX-000 VRM for Optional Microprocessor 4 2. Optional Microprocessor 126 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 137
    any I2C messages (see "I2C bus fault messages" on page 141). 2. Remove ac power from system for 20 seconds, then rerun service processor test. If problem persists, proceed to step 3. 3. I/O Legacy Board. Before replacing the I/O Legacy Board, ensure that I/O Legacy Board jumper J28 is not installed
  • IBM 866631Y | Hardware Maintenance Manual - Page 138
    -ROM Drive Cables 2. CD-ROM Drive 3. I/O Legacy Board 1. Fixed Disk 1 1. Fixed Disk 2 1. Fixed Disk 3 1. Fixed Disk 4 1. Fixed Disk 5 1. Fixed Disk 6 1. Fixed Disk 7 128 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 139
    or power cable connected to the tape drive with SCSI ID NN 3. Tape drive with SCSI ID NN - refer to Help and Service Information appendix of tape drive's User Guide. 4. I/O Legacy Board or SCSI Controller - run SCSI Controller diagnostic to determine of SCSI bus is functioning properly. 264-XXX-999
  • IBM 866631Y | Hardware Maintenance Manual - Page 140
    with 2. Run Video Diagnostics. If diagnostics pass, the problem may be a video driver. the monitor, refer to the 3. Display Adapter / I/O Legacy Board information that comes with the monitor for adjusting and testing instructions. 130 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 141
    the power supply LED information on the following page to troubleshoot power supply problems. Note: The minimum configuration required for the DC Good screen for any POST errors. Check the System Error Log for any listed problems. If the system powers up with no errors: a. Power Switch Assembly 2.
  • IBM 866631Y | Hardware Maintenance Manual - Page 142
    Processor/PCI Board 175 (Hardware error) 1. I/O Legacy Board 2. Processor/PCI Board 176 (Computer cover or cable cover was removed without a key being used) 1. Run Configuration/Setup 2. Set serial number in Setup 2. I/O Legacy Board 132 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 143
    Error Code/Symptom FRU/Action 188 (Bad EEPROM CRC #2) 1. Run Configuration/Setup 2. I/O Legacy Board 189 (An attempt was made to access the server with invalid passwords) 1. Run Configuration/Setup, enter the administrator password 2. I/O Legacy Board. 201 (Memory test error, see ″Memory
  • IBM 866631Y | Hardware Maintenance Manual - Page 144
    Switch Assembly 4. I/O Legacy Board 1600 (The Service Processor is not functioning) Do the following system is able to communicate to the Service Processor, but the Service Processor failed to respond at the -on the system. 2. Flash update the Service Processor. 1. I/O Legacy Board 2. Processor/
  • IBM 866631Y | Hardware Maintenance Manual - Page 145
    /Setup 2. Failing Adapter 3. I/O Legacy Board 1. Verify a bootable operating system is installed. 2. If RAID system, refer to the IBM ServeRAID Hardware Maintenance Manual for more information. 3. Run Diagnostics 4. Hard Disk Drive 5. Cable 6. SCSI Backplane 7. I/O Legacy Board 1. Video Adapter (if
  • IBM 866631Y | Hardware Maintenance Manual - Page 146
    processors are the same stepping level and cache size. 2. Processor 1 1. Ensure all processors are the same stepping level and cache size. 2. Processor 2 136 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 147
    1. Hard Disk Drive 2. If RAID system, refer to the ServeRAID Hardware Maintenance Manual for more information. 3. SCSI Backplane 4. Cable 5. I/O Legacy Board 1. Install , refer to the Hardware Maintenance Manual for the particular RAID adapter in the system being serviced. Symptom-to-FRU index 137
  • IBM 866631Y | Hardware Maintenance Manual - Page 148
    codes Error Code All SCSI Errors One or more of the following might be causing the problem: v A failing SCSI device (adapter, drive, controller) v An improper SCSI configuration or 3). 2. Replace CPU ″X″. 3. Replace Processor/PCI Board. 138 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 149
    Fan error messages Message Fan ″X″ failure (level-critical; fan ″X″ had a failure) Fan ″X″ fault (level-critical; fan ″X″ beyond recommended RPM range) Action 1. Check connections to fan ″X″ 2. Replace fan ″X″ 1. Check connections to fan ″X″ 2. Replace fan ″X″ Power error messages Message Action
  • IBM 866631Y | Hardware Maintenance Manual - Page 150
    the following tables when experiencing system shutdown related to voltage or temperature problems. Power related system shutdown Message System powered off due to ″X″ specifications(see "Features and specifications" on page 3. 2. 140 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 151
    Message Action System shutoff due to DASD temperature (sensor X) (level-critical; DASD area reported temperature outside recommended operating range) 1. Ensure system is being properly cooled, see "Temperature checkout" on page 20. System shutoff due to high ambient temperature (level-critical;
  • IBM 866631Y | Hardware Maintenance Manual - Page 152
    : 1. A corrupt CMOS can cause undetermined problems. 2. A faulty I2C Bus can cause undetermined problems. Check the system error log for any computer and reconfigure each time). Any external devices Surge suppressor device (on the computer) 142 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 153
    Modem, printer, mouse, or non-IBM devices Each adapter Hard disk drives Memory-Modules (Minimum requirement = a minimum of 1 bank of four 128 MB DIMMs (4x128)) 4. Power-on the computer. If the problem remains, suspect the following FRUs in the order listed: Power Supply Power Backplane Processor/PCI
  • IBM 866631Y | Hardware Maintenance Manual - Page 154
    144 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 155
    Parts listing (Type 8666) Part A Note: The illustrations in this document might differ slightly from your hardware. 14 13 12 11 10 9 RENDON DASD1 SPOEVCER SMI MEM PS1 NMI CPU PS2 SP VRM PS3 PCIA FAN PS4 PCIB TEMP PCIC 1 2 3 A 6 7 8 4 5 © Copyright IBM Corp. 1999 145
  • IBM 866631Y | Hardware Maintenance Manual - Page 156
    on page 147. Index 1 2 3 4 5 6 7 8 9 10 11 12 13 14 System (Netfinity 7100 - Type 8666) Models 1RY, 2RY, 11Y, 21Y Hard disk drive fan assembly (Models 1RY, 2RY, 11Y, 21Y) SCSI backplane assembly w/ 09N0881 76H4091 37L0272 37L6328 37L6327 146 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 157
    Part B Note: The illustrations in this document might differ slightly from your hardware. 1 2 3 4 5 6 7 8 12 9 10 11 Parts listing (Type 8666) 147
  • IBM 866631Y | Hardware Maintenance Manual - Page 158
    Misc. processor kit (Models 1RY, 2RY, 11Y, 21Y) (contains processor guide (2), VRM guide (8), VRM guide retainer (4), memory card guide (2)) I/O legacy label (Models 1RY, 2RY, 11Y, 21Y) Processor/PCI board 12J3065 12J3079 28L4567 36L9761 148 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 159
    Index System (Netfinity 7100 - Type 8666) Models 1RY, 2RY, 11Y, 21Y Display bezel (Models 11Y, 21Y) Battery (Models 1RY, 2RY, 11Y, 21Y) Status lens cover 37L2567 37L2568 37L2569 37L2570 37L2571 37L2572 37L2573 37L2574 37L2575 37L2576 37L2577 37L2578 37L2579 37L2580 Parts listing (Type 8666) 149
  • IBM 866631Y | Hardware Maintenance Manual - Page 160
    , Jamaica, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), Venezuela United States of America (110) 1838574 (220) 36L8886 (220V/15A) 150 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 161
    Note: The service procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this manual. © Copyright IBM Corp
  • IBM 866631Y | Hardware Maintenance Manual - Page 162
    with before servicing an IBM mobile computer. General start the machine, ensure that other service representatives and the customer's personnel place, away from all personnel, while you are servicing the machine. v Keep your tool case away to your eyes. v After service, reinstall all safety shields,
  • IBM 866631Y | Hardware Maintenance Manual - Page 163
    frames. Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages from a circuit. First, check that it has been powered-off. Related service information 153
  • IBM 866631Y | Hardware Maintenance Manual - Page 164
    to protect users and service personnel from injury. This guide addresses only those of non-IBM features or options not covered by this inspection guide. If any , broken, or sharp edges). 2. Power-off the computer. Disconnect the power cord. 3. Check the power cord Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 165
    the safety of any non-IBM alterations. 6. Check inside listed below, to provide protection that meets the specific service requirement. Note: The use of a grounding system is ac plug on ac-operated computers. Grounding requirements Electrical grounding of the computer is required for operator safety
  • IBM 866631Y | Hardware Maintenance Manual - Page 166
    read all caution and danger statements before performing any of the instructions. v Statement 1 DANGER Electrical current from power, telephone and 5. Turn device ON. v Statement 2 156 Hardware Maintenance Manual: Netfinity 7100 - Type 8666 To Disconnect 1. Turn everything OFF. 2. First, remove
  • IBM 866631Y | Hardware Maintenance Manual - Page 167
    CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures
  • IBM 866631Y | Hardware Maintenance Manual - Page 168
    source. 2 1 v Statement 10 CAUTION: Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted devices. 158 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 169
    aos conectores. 3. Remova os cabos de sinal dos conectores. 4. Conecte os cabos de alimentação às tomadas. 4. Remova todos os cabos dos dispositivos. 5. LIGUE os dispositivos. Related service information 159
  • IBM 866631Y | Hardware Maintenance Manual - Page 170
    011) 889-8986, para obter informações sobre como enviar a bateria pelo correio para a IBM. Instrução 3 PRECAUCIÓN: Quando produtos a laser (unidades de CD-ROM, unidades de DVD, íticos, e evite exposição direta ao raio. Instrução 4 160 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 171
    fonte de energia elétrica. 2 1 CUIDADO: Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. Related service information 161
  • IBM 866631Y | Hardware Maintenance Manual - Page 172
    162 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 173
    Related service information 163
  • IBM 866631Y | Hardware Maintenance Manual - Page 174
    164 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 175
    Related service information 165
  • IBM 866631Y | Hardware Maintenance Manual - Page 176
    166 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 177
    Related service information 167
  • IBM 866631Y | Hardware Maintenance Manual - Page 178
    168 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 179
    qui la relient aux réseaux, aux systèmes de télécommunication et aux modems (sauf instruction contraire mentionnée dans les procédures d'installation et de configuration). v Lorsque vous installez tous les câbles des unités. prises. 5. Mettez les unités sous tension. Related service information 169
  • IBM 866631Y | Hardware Maintenance Manual - Page 180
    pile au lithium usagée par une pile de référence identique exclusivement - voir la référence IBM - ou par une pile équivalente recommandée par le fabricant. Si votre système est optiques. évitez une exposition directe au rayon. Notice n 4 170 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 181
    plusieurs cordons d'alimentation. Pour isoler totalement l'unité du réseau électrique, débranchez tous les cordons d'alimentation des socles de prise de courant. 2 1 Notice n 10 ATTENTION: Related service information 171
  • IBM 866631Y | Hardware Maintenance Manual - Page 182
    . Kabel l÷sen: 1. Alle Geräte ausschalten. 2. Zuerst Netzstecker von Steckdose l÷sen. 3. Signalkabel von Anschlußbuchsen l÷sen. 4. Alle Kabel von Einheiten l÷sen. Hinweis 2 172 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 183
    ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr sehen, nicht direkt mit optischen Instrumenten betrachten und den Strahlungsbereich meiden. Hinweis 4 Related service information 173
  • IBM 866631Y | Hardware Maintenance Manual - Page 184
    Netzkabel aus den Netzsteckdosen herausgezogen wurden. 2 1 Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. 174 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 185
    . dalle prese elettriche. 4. Collegare i cavi di alimentazione alle prese elettriche. 3. Rimuovere i cavi di segnale dai connettori. 5. ACCENDERE le unità. 4. Rimuovere tutti i cavi dalle unità. Related service information 175
  • IBM 866631Y | Hardware Maintenance Manual - Page 186
    2 ATTENZIONE: Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso tipo o :erev refid=a. di tipo strumenti ottici ed evitare l'esposizione diretta al fascio. Avviso 4 176 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 187
    dalla sorgente di alimentazione. 2 1 Avviso 10 ATTENZIONE: Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in rack. Related service information 177
  • IBM 866631Y | Hardware Maintenance Manual - Page 188
    178 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 189
    Related service information 179
  • IBM 866631Y | Hardware Maintenance Manual - Page 190
    180 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 191
    de señal de los conectores. 4. Conecte cada cable de alimentaciín a la 4. Retire los cables de los dispositivos. toma de alimentaciín. 5. ENCIENDA el dispositivo. Related service information 181
  • IBM 866631Y | Hardware Maintenance Manual - Page 192
    desee sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema tiene un ípticos; evite la exposiciín directa al rayo. 182 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 193
    fuente de alimentaciín. 2 1 Declaración 10 PRECAUCIÓN: No coloque ningún objeto que pese más de 82 kg (180 libras) encima de los dispositivos montados en bastidor. Related service information 183
  • IBM 866631Y | Hardware Maintenance Manual - Page 194
    this survey, complete it, and then fax it to IBM HMM Survey at 919-543-8167 (USA). Name Phone number 1. Do you like this manual? h Yes h No 2. What would you like to see added, changed, or deleted in this manual 3. What is your service experience level? h Less than five years h More than five
  • IBM 866631Y | Hardware Maintenance Manual - Page 195
    in problem determination. If possible, have this information available when requesting assistance from Service Support and IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Subject to IBM
  • IBM 866631Y | Hardware Maintenance Manual - Page 196
    States or other countries or both: HelpCenter IBM NetBAY3 Netfinity Manager SystemXtra HelpFax OS/2 Netfinity ThinkPad The following terms are trademarks of other companies trademark or registered trademark of Microsoft Corporation. 186 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
  • IBM 866631Y | Hardware Maintenance Manual - Page 197
  • IBM 866631Y | Hardware Maintenance Manual - Page 198
    Part Number: 10K2859 Printed in the United States of America on recycled paper containing 10% recovered post-consumer fiber. (1P) P/N: 10K2859
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198

Hardware Maintenance Manual
Netfinity 7100 – Type 8666
IBM