Cause, Action, DIMM error LEDs.
![]() |
UPC - 087944569336
View all IBM 866631Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1. Light path diagnostics (continued) LED Cause Action PCIA An error occurred on PCI bus A. An adapter in PCI slot 1 or 2, or the processor board caused the error. 1. Check the error log for additional information. 2. If you cannot correct the problem from the information in the error log, try to determine the failing adapter by removing one adapter at a time from PCI bus A (PCI slots 1-2) and restarting the server after each adapter is removed. PCIB An error occurred on PCI bus B. An adapter in PCI slot 3, 4, 5, or 6 or the processor board caused the error. 1. Check the error log for additional information. 2. If you cannot correct the problem from the information in the error log, try to determine the failing adapter by removing one adapter at a time from PCI bus B (PCI slots 3-6) and restarting the server after each adapter is removed. PCIC An error occurred on PCI bus C. An error on the processor or I/O board caused the problem. Check the error log for additional information. If the error log indicates a problem with the integrated SCSI controller, the Ethernet controller or video controller, see "Starting the diagnostic programs" on page 14. DASD A hot-swap hard disk drive has failed on SCSI channel B. 1. If the TEMP LED is also on, take the actions listed for that LED. 2. If the amber status LED on one of the hot-swap hard disk drives is on, replace the drive. MEM A memory error occurred. 1. Check the DIMM error LEDs on the memory board. 2. Replace the DIMM indicated by the lit DIMM error LEDs. CPU One of the microprocessors has failed or a microprocessor is installed in the wrong connector. 1. Check the microprocessor error LEDs on the memory board. If a microprocessor error LED is on for a microprocessor connector that has a terminator card installed instead of a microprocessor, the microprocessors are not installed in the correct order. See "Installing a microprocessor kit" on page 57 for information about the correct order for installing microprocessors and VRMs. Otherwise, continue with the next step. 2. Turn off the server, reseat the microprocessor indicated by the lit microprocessor error LED, and restart the server. 3. If the problem persists, replace the microprocessor. VRM One of the voltage regulator modules on the processor board has failed. 1. Check the VRM error LEDs on the processor board. 2. Turn off the server, reseat the VRM indicated by the lit VRM error LED, and restart the server. 3. If the problem persists, replace the VRM. 18 Hardware Maintenance Manual: Netfinity 7100 - Type 8666
![](/manual_guide/products/ibm-866631y-hardware-maintenance-manual-80ad7e3/28.png)