IBM 866631Y Hardware Maintenance Manual - Page 37
NDIS 4.0 (Windows NT) driver messages, No Secondary Adapter Found. Grouping Mode is disabled.
![]() |
UPC - 087944569336
View all IBM 866631Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller (continued) PCNTNW-NW-126 The group bit in the node address override was cleared. Explanation: The IEEE address has a group bit that indicates that an address belongs to a group of stations. This bit is used only as a destination address; it cannot be used as a source address. You tried to enter a source address with this bit set. The driver cleared the group bit of the source address. Action: None necessary, message is for information only. PCNTNW-NW-127 The local bit in the node address override was set. Explanation: The local bit in the IEEE address format indicates that the addresses are being managed locally. If you use the node address override capabilities of this driver to enter a new address, the local bit must be set. You entered an address without the local bit set. The driver has set the local bit. Action: None necessary, message is for information only. PCNTNW-NW-164 The device was not found. Explanation: The driver cannot find an Ethernet controller in the server. Action:Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-165 The device was not found at IOADDRESS. Explanation: The Ethernet controller cannot be found at the I/O address specified. Action:The Ethernet controller does not require a parameter for the I/O address. Remove the I/O address parameter. PCNTNW-NW-167 PCI scan specified, device not found. Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action:Verify that the Ethernet controller is enabled. If the problem persists, go to "Starting the diagnostic programs" on page 14 to run the diagnostic programs. PCNTNW-NW-180 The DMA parameter is not necessary for PCI device. Explanation: The Ethernet controller does not require a DMA setting. Action:None necessary, message is for information only. NDIS 4.0 (Windows NT) driver messages This section contains the error messages for the NDIS 4.0 drivers. The explanation and recommended action are included with each message. Table 4. NDIS (Windows NT) driver messages for the Ethernet controller PermaNet™ Server: No Secondary Adapter Found. Grouping Mode is disabled. Explanation:The failover option requires an adapter that is compatible with the device driver of the Ethernet controller on the system board. No such adapter was found. Action:Make sure the correct adapter is installed. Diagnostics 27
![](/manual_guide/products/ibm-866631y-hardware-maintenance-manual-80ad7e3/37.png)