IBM 866631Y Hardware Maintenance Manual - Page 71
Replacing a hot-swap fan
UPC - 087944569336
View all IBM 866631Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Refer to the following illustration to install a hot-swap power supply. Handle DC power light AC power light Filler panel To install an additional power supply: 1. Review "Before you begin" on page 43. 2. Remove the filler panel. 3. Place the handle on the power supply in the open position. 4. Slide the power supply into the chassis and close the handle. 5. Plug one end of the power cord into the power supply; then, plug the other end of the cord into a properly grounded electrical outlet. 6. Verify that the DC power light and the AC power light on the power supply are lit, indicating that the power supply is operating properly. CAUTION: If you install a strain-relief bracket option over the end of the power cord that is connected to the device, you must connect the other end of the power cord to an easily accessible power source. Replacing a hot-swap fan Before you begin: v Read "Safety information" on page 152. v Review the information in "Before you begin" on page 43. v Read the documentation that comes with the option. Installing options 61