IBM IC35L040AVVN07-0 Hard Drive Specifications - Page 193
Time-out, Value
UPC - 683728124212
View all IBM IC35L040AVVN07-0 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 193 highlights
Output Parameters To The Drive Sector Count Time-out Parameter. If it is 0, the automatic power down sequence is disabled. If it is nonzero, the automatic power down sequence is enabled. The time-out interval is shown below: Value 0 1-240 241-251 252 253 254 255 Time-out Timer disabled Value x 5 seconds (Value-240) x 30 minutes 21 minutes 8 hours 21 minutes 10 seconds 21 minutes 15 seconds When the automatic power down sequence is enabled, the drive will enter Standby mode automatically if the time-out interval expires with no drive access from the host. The time-out interval will be reinitialized if there is a drive access before the time-out interval expires. Deskstar 120GXP hard disk drive specifications 179
Output Parameters To The Drive
Sector Count
Time-out Parameter. If it is 0, the automatic power down sequence is disabled. If
it is nonzero, the automatic power down sequence is enabled.
The time-out
interval is shown below:
21 minutes 15 seconds
255
21 minutes 10 seconds
254
8 hours
253
21 minutes
252
(Value-240) x 30 minutes
241-251
Value x 5 seconds
1-240
Timer disabled
0
Time-out
Value
When the automatic power down sequence is enabled, the drive will enter
Standby mode automatically if the time-out interval expires with no drive access
from the host. The time-out interval will be reinitialized if there is a drive access
before the time-out interval expires.
Deskstar 120GXP hard disk drive specifications
179