Icom IC-F5061D Operating Guide - Page 17
■ Stun function, ■ BIIS indication, ■ Priority A channel selection
View all Icom IC-F5061D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
BIIS 1200 OPERATION 2 ■ Stun function ■ Priority A channel selection 1 When the specified ID, set as a killer ID, is received, the stun When one of the following operations is performed, the trans- 2 function is activated. ceiver automatically selects the Priority A channel. 3 When a killer ID is received, the transceiver switches to the Priority A is selected when: 4 password required condition. Entering the password with the keypad is necessary to operate the transceiver again in this • A clear down signal is received or transmitted - Set the 'Clear down' option as 'Enable' in 'Move to PrioA 5 case. ■ BIIS indicators The following indicators are available for the BIIS operation on an MSK channel. CONNECT : Individual/group calls are successful. OK : Message (status or SDM) transmission was CH.' 6 • Turning the power ON Priority A channel is selected each time the transceiver 7 power is turned ON. 8 • Status call Priority A channel is selected when transmitting a status 9 call. 10 - Enable the 'Send Status on PrioA CH' item in the MSK configuration. 11 successful. 12 FAILED : No answer back is received. 13 WAIT : Appears during retry of the call (2nd call). CLR DOWN : End the call. 14 BUSY : The operating channel is busy. 15 16 14