Icom IC-M506 Instruction Manual - Page 114
MB-75/MB-132 installation
View all Icom IC-M506 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 114 highlights
12 CONNECTIONS AND MAINTENANCE ■■MB-75/MB-132 installation An optional MB-75/MB-132 flush mount KIT is available for mounting the transceiver to a flat surface such as an instrument panel. KEEP the transceiver and microphone at least 1 meter (3.3 feet) away from the vessel's magnetic navigation compass. q U sing the template on page 112, carefully cut a hole into the instrument panel, or wherever you plan to mount the transceiver. w Slide the transceiver through the hole, as shown below. D MB-75 installation q A ttach the 2 supplied bolts (M5 × 8 mm) on either side of the transceiver. w A ttach the clamps on either side of the transceiver. • Make sure that the clamps align parallel to the transceiver's body. Supplied bolt w Clamp w e T ighten the end bolts on the clamps (rotate clockwise) so that the clamps press firmly against the inside of the instrument control panel. (Torque: 0.6 N•m) r T ighten the locking nuts (rotate counterclockwise) so that the transceiver is securely mounted in position as below. t C onnect the antenna and power cable, then return the instrument control panel to its original place. 105