Icom IC-M506 Instruction Manual - Page 79
DDSC Data Output DAlarm Status, tion, List Station or OFF
View all Icom IC-M506 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
DSC OPERATION 7 D DSC Data Output Select an option for the DSC Data Output function. When receiving a DSC call, this function makes the transceiver send the DSC data from its NMEA Output port to a connected device. q E nter "DSC DATA OUTPUT" in the DSC Settings menu. MENU ➪ DSC SET ➪ DSC Data Output (Push [MENU]) (Select icon) (Rotate dial, then push [ENT].) w R otate dial to set the DSC Data Output function to "All Station," "List Station" or "OFF," then push [ENT]. • Push [BACK] to cancel and return to the DSC Settings menu. (default) All Stations: Outputs the call from any vessel from the NMEA Output port. Station List: Outputs the call from any vessels listed on the Individual ID screen. OFF: Does not output any call to the external equip- ment. eePush [EXIT] to return to the normal operating mode. D Alarm Status 1 Set the Alarm function ON or OFF, depending on the Category or Status. 2 3 q E nter "ALARM STATUS" in the DSC Settings menu. MENU ➪ DSC SET ➪ Alarm 4 (Push [MENU]) (Select icon) (Rotate dial, then push [ENT].) 5 w R otate dial to select the status, then push [ENT]. 6 • Push [BACK] to cancel and return to the DSC Settings menu. • "Safety," "Routine," "Warning," "Self-Terminate" and "Discrete" are 7 selectable. (default: ON) 8 9 10 11 12 eeRotate dial to set the Alarm setting to "ON" or "OFF." 13 rrPush [EXIT] to return to the normal operating mode. 14 15 16 70