Icom VE-PG3 Instruction Manual - Page 15
Operation in the Unicast mode, 1. Configuration
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
2 BRIDGE MODE APPLICATION 2. Operation in the Unicast mode In the Unicast mode, you can call the designated radio, using a communication port. • In the instruction, the example of the communication as illustrated below, is used. Area A Area B [TRX1] Radio A Radio A1 VE-PG3 (192.168.0.2) IP Network [TRX1] VE-PG3 (192.168.0.3) Radio B Radio B1 An example of communication the Unicast mode 1. Configuration Access the VE-PG3 setting screen, and set the items as shown below. VE-PG3 (Area A) Menu Item Setting Screen Setting Item Item Name Value Operating Mode Operating Mode Operating Mode Operating Mode Bridge IP Communication Mode IP Communication Mode Unicast Port Settings Transceiver 1 (TRX1) Transceiver Model Transceiver Model IC-F5060 Bridge Connection Bridge Connection Bridge Connection Point Connection IP Address* 192.168.0.3 Connection Port Number 21500 My Station Port Number 21500 List of Bridge Connection Point Entries Connection Status** "During transmit" *Enter the IP address of VE-PG3 in area A (ex. 192.168.0.2) for the VE-PG3 in area B. **Click [Connect], and verify that "During transmit" is displayed. Click 2-5