Icom VE-PG3 Instruction Manual - Page 300
Control Output, Monitor Period, IP Address
![]() |
View all Icom VE-PG3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 300 highlights
6 CONVERTER MODE SETTING SCREEN 10. [Expansion] Menu (continued) M Abnormal Condition Monitoring (continued) [Expansion]-[Abnormal Condition Monitoring] • This is an example. wPING test Select "Enable" to send the PING commands to the specified IP address. (Default: Disable) When the Ethernet cable disconnects from the VE-PG3's [LAN] port, the [WAN] LED blinks Orange, and the error message is displayed on the "SYSLOG" screen in the "Information" menu. Control Output Select "Enable" to output the error detect signal from the B1/B2 terminal (+/-). (Default: Disable) • Select "Relay circuit" in the Control Circuit] item on the [EXT Output] (1/2), or [EXT I/O] (1/2) screen. While the error detect signal is sent, the VE-PG3 cannot receive signals from the external device that is connected to the B1/B2 terminal (+/-). IP Address: Enter the destination IP address to send the commands. Monitor Period: Set the monitor period between 1 to 4320 minutes. (Default: 10) 6-121
![](/manual_guide/products/icom-vepg3-instruction-manual-789cf72/300.png)