InSinkErator Invite H990-SS Owners Manual - Page 13

Care And Use

Page 13 highlights

CARE AND USE Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarized electric outlet. ADJUSTING THE THERMOSTAT Factory temperature pre-set is 200˚F. To reset the thermostat to 200°, turn the indicator two notches to the right of vertical. approx. 200° I Adjust the thermostat slowly, turning the dial clockwise to increase temperature or counter clockwise to decrease temperature, then activate faucet handle for 20 seconds to bring in fresh water to be heated at the new setting. Allow 5-7 minutes for water to reach new temperature. Scalding Hazard: Do not allow water to boil. May result in severe burns. SEASONAL STORAGE/DRAINAGE Anytime the instant hot water dispenser is not used for extended periods of time, unplug and drain unit. If it is below freezing you will need to unplug the unit and drain it. I Disconnect power from unit. I Push hot water dispenser faucet lever and allow water to flow until it is cool. I Shut the cold water supply off at the valve. I Locate and remove drain screw from bottom center of water tank and drain the water into empty pail. I Empty the tank and then reinstall drain screw into the bottom of tank, turning until snug. Do NOT over tighten. I If filter system installed, remove and discard filter cartridge. I To put back into working order, install new filter cartridge (if required), fill tank with water and reconnect the electrical cord. (Refer to Page 11, Step 6) PROPERTY DAMAGE I Regularly inspect the unit for any signs of leakage. If there are signs of water damage, immediately remove the unit from service. I To avoid water damage from leakage, replace all cut, loose or split tubing. I A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage. CLEANING THE FAUCET AND TANK I Only use mild cleaners to clean the faucet and plastic components. I Cleaners with acids, abrasives, alkaline or organic solvents will result in deterioration of the plastic components and void the warranty. For fresher tasting water, add filtration to your instant hot water dispenser system. InSinkErator offers the only water filtration system designed specifically for instant hot water dispensers. For more information, visit www.insinkerator.com. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

13
Electric Shock Hazard:
To prevent electrical shock, disconnect power before
servicing unit. Use only a properly grounded and polarized electric outlet.
Scalding Hazard:
Do not allow
water to boil. May result in
severe burns.
Factory temperature pre-set
is 200˚F.
To reset the
thermostat to 200°, turn
the indicator two notches
to the right of vertical.
Adjust the thermostat
slowly, turning the dial
clockwise to increase temperature
or counter clockwise to decrease
temperature, then activate faucet
handle for 20 seconds to bring in fresh
water to be heated at the new setting.
Allow 5-7 minutes for water to reach
new temperature.
Regularly inspect the unit for any signs
of leakage. If there are signs of water
damage, immediately remove the unit
from service.
To avoid water damage from leakage,
replace all cut, loose or split tubing
.
A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector,
should be used in those applications
where any leakage could cause
property damage.
PROPERTY DAMAGE
CARE AND USE
approx. 200°
Only use mild cleaners to clean the
faucet and plastic components.
Cleaners with acids, abrasives,
alkaline or organic solvents will
result in deterioration of the plastic
components and void the warranty.
CLEANING THE FAUCET AND TANK
Anytime the instant hot water dispenser is not
used for extended periods of time, unplug and
drain unit. If it is below freezing you will need to
unplug the unit and drain it.
Disconnect power from unit.
Push hot water dispenser faucet lever
and allow water to flow until it is cool.
Shut the cold water supply off at the valve.
Locate and remove drain screw from
bottom center of water tank and drain
the water into empty pail.
Empty the tank and then reinstall drain
screw into the bottom of tank, turning
until snug. Do NOT over tighten.
If filter system installed, remove and
discard filter cartridge.
To put back into working order, install
new filter cartridge (if required), fill tank
with water and reconnect the electrical
cord. (Refer to Page 11, Step 6)
SEASONAL STORAGE/DRAINAGE
ADJUSTING THE THERMOSTAT
For fresher tasting water, add filtration to
your instant hot water dispenser system.
InSinkErator offers the only water filtration
system designed specifically for instant
hot water dispensers. For more information,
visit www.insinkerator.com.