Invacare TDXSP2V Owners Manual 2 - Page 65
Footrest Height Adjustment, 9.6.1 Model 70NHD, Inches Out
View all Invacare TDXSP2V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
telescoping front rigging support to the seat frame as shown in the figure. 4. If necessary, repeat steps 1-3 on remaining telescoping front rigging support. Standard Position 18 inches wide Holes 2 and 3 20 inches wide Holes 2 and 3 22 inches wide Holes 3 and 4 1 Inch Out Holes 3 and 4 Holes 3 and 4 Holes 5 and 6 2 Inches Out Holes 4 and 5 Holes 4 and 5 Holes 6 and 7 9.6 Footrest Height Adjustment WARNING! Operating the wheelchair with a clearance of less than 75 mm (3 inches) between the footplates and the ground/floor may cause serious injury or property damage. -ALWAYS maintain a minimum of 75 mm (3 inches) between the bottom of the footplates and ground/floor to ensure proper clearance while the wheelchair is in motion. If necessary, adjust the 60101876-C 9 Service footplate height to achieve proper clearance. After footplate height adjustment, if the wheelchair dips forward and the footplates touch the ground while in motion, please contact your provider for an inspection and avoid use of the wheelchair if possible. 9.6.1 Model 70NHD 1. Remove any accessory from the footrest(s). Lay the footrest on a flat surface to simplify this procedure. 2. Remove the front rigging from the wheelchair. 3. Remove the hex bolt A, washers B, and locknut C that 65