Kenmore 75121 Owners Manual - Page 4

Observe - ac

Page 4 highlights

OBSERVAELL LOCAL CODESAND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES,REMOVE THE POWERSUPPLY CORD GROUND PRONG. ELECTRICALGROUND IS REQUIREDON THIS APPLIANCE. For 230/208volt 60 Hz,AC only, 15A fused and properlygrounded electricalsupply is required.A time delay fuse or time delay circuit breaker is recommended.Use a dedicated circuit, serving only this appliance. DO NOT USEAN EXTENSIONCORD. 115V- 230V- x=J RECOMMENDEDGROUNDINGMETHOD Foryourpersonalsafety,this appliancemustbegrounded. This appliancehasa powersupplycordwitha 3-prong groundingplug.To minimizepossibleshockhazard,the cordmustbe pluggedintoa matinggroundingtypewall receptacleand groundedin accordancewiththe National ElectricaCl ode(ANSI/NFPA70) latesteditionand all local codesandordinancesI.f a matingwall receptacleis not available,it isthe personalresponsibilityand obligationof the customerto havea properlygrounded3-prongwall receptacleinstalledbya qualifiedelectrician. Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. NOTE: The shape may be different according to its model. Use Wall Receptacle Power Supply 3-wire grounding Sretcaenpdtaarcdle12ra5tVed, 15A, 125V AC Standard 250V, 3-wire grounding receptacle r_ed 15A,250V AC Standard 250V, 3-wire grounding receptacle rated 20A, 250V AC Use 15 AMP. time delay fuse or 15 AMP. circuit breaker. Use 20 AMP. time delay fuse or 20 AMP. circuit breaker. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. You can choose between two methods below according to your window stool shape and preference. USING SLIT "A" USING SLIT "B" Fasten the stopper using 1 screw holes, and lead Fasten the stopper using left screw hole, and rotate out the power cord through slit "A". properly to lead the power cord out through slit "B". 0 -4-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

OBSERVE
ALL LOCAL
CODES
AND ORDINANCES.
DO NOT, UNDER ANY
CIRCUMSTANCES,
REMOVE
THE POWERSUPPLY CORD GROUND PRONG.
ELECTRICALGROUNDISREQUIREDONTHIS
APPLIANCE.
For 230/208volt 60 Hz,AC only, 15A fused and
properlygrounded electricalsupply is required.A time
delay fuse or time delay circuit breaker is
recommended.Useadedicatedcircuit,servingonly
thisappliance.
DO NOT USEAN EXTENSIONCORD.
x=J
115V-
230V-
RECOMMENDEDGROUNDINGMETHOD
Foryourpersonalsafety,thisappliancemustbegrounded.
Thisappliancehasa powersupplycordwitha 3-prong
groundingplug.Tominimizepossibleshockhazard,the
cordmustbeplugged
intoamatinggroundingtypewall
receptacleandgrounded
inaccordancewiththeNational
Electrical
Code(ANSI/NFPA70)latesteditionandalllocal
codesandordinances.
If amatingwall receptacle
is not
available,itisthepersonalresponsibilityandobligationof
thecustomertohaveaproperlygrounded3-prongwall
receptacle
installedbyaqualifiedelectrician.
Power cord may include a current interrupter
device. A test and reset button is provided on the
plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner and
contact a qualified service technician.
NOTE:
The shape may be different according to its model.
Use Wall
Receptacle
Power
Supply
Standard 125V,
3-wire grounding
receptacle rated
15A, 125V AC
Standard 250V,
3-wire grounding
receptacle r_ed
15A,250V AC
Standard 250V,
3-wire grounding
receptacle rated
20A, 250V AC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
circuit breaker.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
You can choose
between two methods
below according
to your window
stool shape and preference.
USING
SLIT
"A"
Fasten the stopper
using 1 screw holes, and lead
out the power cord through
slit "A".
USING
SLIT
"B"
Fasten the stopper using left screw
hole, and rotate
properly
to lead the power cord out through
slit "B".
0
-4-