Kenwood KXF-W6010 User Manual - Page 4

Important items, Maintenance, Reference

Page 4 highlights

Important items 4 Maintenance Cleaning Unplug this appliance from the wall outlet before cleaning. Do not use volatile solvents such as alcohol, paint thinner, gasoline, or benzine, etc. to clean the cabinet. Use a clean dry cloth. CT-2050/203/KXF-W6010/W4010 (En/M) Caution against contact revitalizer Do not use contact cleaners because it could cause a malfunction. Be specially careful against contact cleaners containing oil, for they may deform the plastic componente. Cleaning the head section Cotton swab Capstan Head Pinch roller Tape guides Cleaning the heads and peripheral components For maintaining the best condition of the deck and for longer service life, always keep the head (recording/playback/erase), capstan and pinch roller clean. To clean them, perform the following: 1. Open the cassette holder. 2. Using a cotton swab dipped in alcohol, clean the head (recording/playback/erase), capstan and pinch roller carefully. Demagnetizing the head When the recording/playback head is magnetized, the sound quality will be deteriorated. In such a case, demagnetize the head using a commercially available demagnetizer (head eraser). Note There are precisely aligned parts around the heads, including the tape guides. When cleaning, pay special attention so as not to apply shock to them. Reference Caution on condensation Condensation (of dew) may occur inside the unit when there is a great difference in temperature between this unit and the outside. This unit may not function properly if condensation occurs. In this case, leave the unit for a few hours with the power left ON, and restart the operation after the condensation has dried up. Be specially cautions against condensation in a following circumstance: When this unit is carried from a place to another across a large difference in temperature, when the humidity in the room where this unit in installed increases, etc. Dolby noise reduction and HX Pro headroom extension manufactured under license from Dolby Laboratories Licensing Corporation. HX Pro originated by Bang & Olufsen. "DOLBY", the double-D symbol and "HX PRO" are trademarks of Dolby Laboratories Licensing Corporation. WARNING NOTICE: IN MOST CASES IT IS AN INFRINGMENT OF COPYRIGHT TO MAKE COPIES OF TAPES OR DISCS WITHOUT THE PERMISSION OF THE COPYRIGHT OWNERS. ANYONE WISHING TO COPY COMMERCIALLY AVAILABLE TAPES OR DISCS SHOULD CONTACT THE MECHANICAL COPYRIGHT PROTECTION SOCIETY LIMITED OR THE PERFORMING RIGHTS SOCIETY LIMITED.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

CT-2050/203/KXF-W6010/W4010 (En/M)
4
Caution on condensation
Condensation (of dew) may occur inside the unit when there is a great
difference in temperature between this unit and the outside.
This unit may not function properly if condensation occurs. In this
case, leave the unit for a few hours with the power left ON, and restart
the operation after the condensation has dried up.
Be specially cautions against condensation in a following cir-
cumstance:
When this unit is carried from a place to another across a large
difference in temperature, when the humidity in the room where this
unit in installed increases, etc.
Important items
Cleaning the heads and peripheral com-
ponents
For maintaining the best condition of the deck and
for longer service life, always keep the head (record-
ing/playback/erase), capstan and pinch roller clean.
To clean them, perform the following:
1. Open the cassette holder.
2. Using a cotton swab dipped in alcohol, clean the
head (recording/playback/erase), capstan and
pinch roller carefully.
Demagnetizing the head
When the recording/playback head is magnetized,
the sound quality will be deteriorated. In such a
case, demagnetize the head using a commercially
available demagnetizer (head eraser).
Capstan
There are precisely aligned parts around
the heads, including the tape guides.
When cleaning, pay special attention so
as not to apply shock to them.
Cotton swab
Pinch roller
Tape guides
Head
WARNING NOTICE:
IN MOST CASES IT IS AN INFRINGMENT OF COPYRIGHT
TO MAKE COPIES OF TAPES OR DISCS WITHOUT THE
PERMISSION OF THE COPYRIGHT OWNERS. ANYONE
WISHING TO COPY COMMERCIALLY AVAILABLE
TAPES
OR DISCS SHOULD CONTACT THE MECHANICAL COPY-
RIGHT PROTECTION SOCIETY LIMITED OR THE PER-
FORMING RIGHTS SOCIETY LIMITED.
Dolby noise reduction and HX Pro headroom extension manufac-
tured under license from Dolby Laboratories Licensing Corporation.
HX Pro originated by Bang & Olufsen.
“DOLBY”, the double-D symbol
and “HX PRO” are trademarks of
Dolby Laboratories Licensing Corporation.
Cleaning the head section
Cleaning
Unplug this appliance from the wall outlet before cleaning. Do not
use volatile solvents such as alcohol, paint thinner, gasoline, or
benzine, etc. to clean the cabinet. Use a clean dry cloth.
Caution against contact revitalizer
Do not use contact cleaners because it could cause a malfunction.
Be specially careful against contact cleaners containing oil, for they
may deform the plastic componente.
Maintenance
Reference
Note