Kenwood TS-870S User Manual - Page 100
Selects receive/transmit mode., RX, TX, RX/TX
![]() |
View all Kenwood TS-870S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Function Input Output Function Input Output Function ● APPENDICES RA RF ATTENUATOR Sets or reads RF ATT(attenuator). Parameter Format Parameter function P1 48 ATTENUATOR RT RIT Sets RIT OFF/ON or reads status. Parameter Format Parameter function P1 1 RIT OFF/ON Function Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R A P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RA ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R A P1 ; Input Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R T P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RT ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R T P1 ; Answer Read Answer Read Output RC RIT CLEAR Set Sets the RIT frequency shift to 0. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RC ; Parameter Format Parameter function Note: This command also clears the XIT frequency (same as RIT shift). The command functions independently from the RIT/XIT control. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Input Function RX TX RX, TX Selects receive/transmit mode. Parameter Format Parameter function Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RX/TX ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RX/TX ; Answer Read Answer Read Output RD RU RIT DOWN/UP Set Lowers/raises RIT frequency. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R D/U ; Parameter Format Parameter function Note: This command also affects the XIT frequency (same as RIT shift). The command functions independently from the RIT/XIT control. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Input Function SC SCAN Sets Scan OFF/ON or reads status. Parameter Format Parameter function P1 1 SCAN OFF/ON Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 S C P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SC ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 S C P1 ; Answer Read Answer Read Output RG RF GAIN Sets or reads RF gain. Parameter Format Parameter function P1 31 RF GAIN Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R G P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RG ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R G P1 ; Input Function SD SEMI BREAK-IN DELAY TIME Sets or reads Semi Break-in delay time. Parameter Format Parameter function P1 49 SEMI BREAK-IN DELAY TIME Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SD P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SD ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SD P1 ; Answer Read Answer Read Output RM READ METER Selects a meter function or reads meter values. Parameter Format Parameter function P1 24 METER SWITCH P2 22 METER VALUE Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R M P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RM ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 R M P1 P2 ; Input Function SM S-METER S-meter and TX RF meter readings. Parameter Format Parameter function P1 22 S-METER VALUE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SM ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SM P1 ; Input Output Function Input Output Function Input Answer Read Answer Read Output Output 94
![](/manual_guide/products/kenwood-ts870s-user-manual-02fc205/100.png)