Tunnel – Serial Settings, To con serial settings, Submit.
View all Lantronix EDS1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
8: Line and Tunnel Settings Tunnel - Serial Settings Serial line settings are configurable for the corresponding serial line of the selected tunnel. Configure the buffer size to change the maximum amount of data the serial port stores. For any active connection, the device sends the data in the buffer. The modem control signal DTR on the Line may be continuously asserted or asserted only while either an Accept Mode tunnel or a Connect Mode tunnel is connected. To configure serial settings: 1. Click Tunnel > Serial Settings at the top of the page. The Tunnel 1 Serial Settings page appears. Figure 8-7 Tunnel 1 Serial Settings 2. View or modify the following settings: Tunnel - Serial Settings Line Settings (display only) Protocol (display only) DTR Description Current serial settings for the line. The protocol being used on the line. In this case, Tunnel. Select when to assert DTR. Unasserted = never asserted TruPort = asserted whenever either a connect or an accept mode tunnel connection is active with the Telnet Protocol RFC2217 saying that the remote DSR is asserted. Asserted while connected = asserted whenever either a connect or an accept mode tunnel connection is active. Continuously asserted = asserted regardless of the status of a tunnel connection. 3. Click Submit. EDS1100/2100 User Guide 49