Lantronix EDS1100 EDS1100 / EDS2100 - User Guide - Page 56

Tunnel – Connect Mode, AES encryption over TCP and UDP, Telnet, Disable, Always, Any Character

Page 56 highlights

8: Line and Tunnel Settings Tunnel - Connect Mode Connect Mode defines how the device makes an outgoing connection. When enabled, Connect Mode is always on and attempting a network connection if the connection mode condition warrants it. For Connect Mode to function, it must:  Be enabled  Have a remote host configured  Have a remote port is configured Enter the remote host address as an IP address or DNS name. The EDS1100/2100 device will make a connection only if it can resolve the address. For DNS names, the EDS1100/2100 will reevaluate the address after being established for 4 hours. If re-evaluation results in a different address, it will close the connection. Connect Mode supports the following protocols:  TCP  AES encryption over TCP and UDP When setting AES encryption, both the encrypt key and the decrypt key must be specified. The encrypt key is used for data sent out. The decrypt key is used for receiving data. Both of the keys may be set to the same value.  SSH To configure SSH, the SSH client username must be configured. In Connect Mode, the EDS1100/2100 is the SSH client. Ensure the EDS1100/2100 SSH client username is configured on the remote SSH server before using it with the EDS1100/2100.  SSL  UDP Is only available in Connect Mode because it is a connectionless protocol. For Connect Mode using UDP, the EDS1100/2100 accepts packets from any device on the network. It will send packets to the last device that sent it packets.  Telnet Note: The Local Port in Connect Mode is independent of the port configured in Accept Mode. There are six different connect modes:  Disable No connection is attempted.  Always A connection is always attempted.  Any Character A connection is attempted if it detects any character from the serial port. Note: While in the "Any Character" or "Start Character" connection modes, the EDS1100/2100 waits and retries the connection if the connection cannot be made. Once it makes a connection and then disconnects, it will not reconnect until it sees another character or the start character again (depending on the configured setting).  Start Character A connection is attempted if it detects a specific and configurable character from the serial port. EDS1100/2100 User Guide 56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

8: Line and Tunnel Settings
EDS1100/2100 User Guide
56
Tunnel – Connect Mode
Connect Mode defines how the device makes an outgoing connection. When enabled, Connect
Mode is always on and attempting a network connection if the connection mode condition warrants
it. For Connect Mode to function, it must:
Be enabled
Have a remote host configured
Have a remote port is configured
Enter the remote host address as an IP address or DNS name. The EDS1100/2100 device will
make a connection only if it can resolve the address. For DNS names, the EDS1100/2100 will re-
evaluate the address after being established for 4 hours. If re-evaluation results in a different
address, it will close the connection.
Connect Mode supports the following protocols:
TCP
AES encryption over TCP and UDP
When setting AES encryption, both the encrypt key and the decrypt key must be specified.
The encrypt key is used for data sent out. The decrypt key is used for receiving data. Both of
the keys may be set to the same value.
SSH
To configure SSH, the SSH client username must be configured. In Connect Mode, the
EDS1100/2100 is the SSH client. Ensure the EDS1100/2100 SSH client username is
configured on the remote SSH server before using it with the EDS1100/2100.
SSL
UDP
Is only available in Connect Mode because it is a connectionless protocol. For Connect Mode
using UDP, the EDS1100/2100 accepts packets from any device on the network. It will send
packets to the last device that sent it packets.
Telnet
Note:
The Local Port in Connect Mode is independent of the port configured in Accept
Mode.
There are six different connect modes:
Disable
No connection is attempted.
Always
A connection is always attempted.
Any Character
A connection is attempted if it detects any
character from the serial port.
Start Character
A connection is attempted if it detects a specific and configurable character from the serial
port.
Note:
While in the “Any Character” or “Start
Character” connection modes, the
EDS1100/2100 waits and retries the
connection if the connection cannot be
made. Once it makes a connection and then
disconnects, it will not reconnect until it sees
another character or the start character