Lantronix EDS32PR EDS - Command Reference - Page 183

default interface, Restores the default of no flow control.

Page 183 highlights

baud rate clear line counters clrscrn command mode always command mode echo serial string disable command mode echo serial string enable command mode serial string command mode serial string command mode serial string binary command mode signon message command mode signon message binary command mode wait time configure current settings data bits 7 data bits 8 default baud rate default data bits default flow control default interface default parity default protocol default stop bits default threshold default xoff char default xon char exit flow control hardware flow control none flow control software gap timer EDS Command Reference 5: Commands and Levels Sets the line speed. = the speed. Standard speeds include 1200, 2400, 4800, 9600, 19200, and so on. Sets the serial counters to zero. Clears the screen. Sets the current line to always be in command mode. Disables user-defined serial boot string to be echoed in the CLI. Enables user-defined serial boot string to be echoed in the CLI. Enables user to enter a custom string at boot time to enter command mode. Sets a string that can be entered at boot time to enter command mode. = text. Sets a binary string that can be entered at boot time to enter command mode. = string that may contain binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Sets an ASCII sign-on message that is sent from the serial port when the device boots and when the line is in command mode. = text. Sets a binary sign-on message that is sent from the serial port when the device boots and when the line is in command mode. = string that may contain binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Sets boot-up wait time for command mode serial string. = wait time. Configures line with the current value of settings. Uses seven bits for data on the line. Uses eight bits for data on the line. Restores the default speed of 9600 bits per second. Restores the default of eight data bits. Restores the default of no flow control. Restores the default interface type to this line. Restores the default of no parity. Restores the default protocol on the line. Restores the default of one stop bit. Restores the factory default threshold. Restores the default xoff character on this line. Restores the default xon character on this line. Exits to the enable level Uses hardware (RTS/CTS) flow control on the line. Does not provide flow control on the line. Uses software (xon/xoff characters) flow control on the line. Sets the gap timer in milliseconds. If some data has been received, it will be forwarded after this time since the last character. 183

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

5:
Commands and Levels
EDS Command Reference
183
baud rate
<bits per second>
Sets the line speed.
<bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200,
and so on.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in the
CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode.
<string> = text.
command mode serial string binary
<string>
Sets a binary string that can be entered at boot time to
enter command mode.
<string> = string that may contain binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode signon message
<string>
Sets an ASCII sign-on message that is sent from the
serial port when the
device boots and when the line is in command mode.
<string> = text.
command mode signon message binary
<string>
Sets a binary sign-on message that is sent from the serial
port when the
device boots and when the line is in command mode.
<string> = string that may contain binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default interface
Restores the default interface type to this line.
default parity
Restores the default of no parity.
default protocol
Restores the default protocol on the line.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been
received, it will
be forwarded after this time since the last character.