Lantronix EDS32PR EDS - Command Reference - Page 70

disconnect tunnel-disconnect:4 level commands, Disables disconnect after timeout feature for tunneling

Page 70 highlights

5: Commands and Levels show history write disconnect (tunnel-disconnect:4) level commands clrscrn exit flush serial disable flush serial enable flush stop character disable flush stop character enable modem control disable modem control enable no stop character no timeout show show history stop character timeout write disconnect (tunnel-disconnect:3) level commands clrscrn exit flush serial disable flush serial enable flush stop character disable flush stop character enable modem control disable modem control enable no stop character no timeout show show history Displays the last 20 commands entered during the current CLI session. Stores the current configuration in permanent memory. Clears the screen. Returns to the tunnel level. Does not flush serial data upon closing a tunneling connection. Flushes serial data buffer when a tunneling connection is closed. Forwards the stop character from the Line to the network. Prevents the stop character from the Line from being forwarded to the network. Does not watch the modem control pin to disconnect. Watches the modem control pin and disconnects if it is not asserted. Removes the stop character. Disables disconnect after timeout feature for tunneling sessions. Displays the current configuration. Displays the last 20 commands entered during the current CLI session. Sets the stop character. The character may be input as text, control, decimal, or hex. A control character has the form C. A decimal value character has the form \99. A hex value character has the form 0xFF. Disconnects when no data has been received on the line (serial port) for the specified length of time. = timeout in milliseconds. Stores the current configuration in permanent memory. Clears the screen. Returns to the tunnel level. Does not flush serial data upon closing a tunneling connection. Flushes serial data buffer when a tunneling connection is closed. Forwards the stop character from the Line to the network. Prevents the stop character from the Line from being forwarded to the network. Does not watch the modem control pin to disconnect. Watches the modem control pin and disconnects if it is not asserted. Removes the stop character. Disables disconnect after timeout feature for tunneling sessions. Displays the current configuration. Displays the last 20 commands entered during the current CLI session. EDS Command Reference 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

5:
Commands and Levels
EDS Command Reference
70
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
disconnect (tunnel-disconnect:4) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling
connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is
closed.
flush stop character disable
Forwards the stop character from the Line to the network.
flush stop character enable
Prevents the stop character from the Line from being
forwarded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not
asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling
sessions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
stop character
<control>
Sets the stop character.
The character may be input as text, control, decimal, or
hex.
A control character has the form <control>C.
A decimal value character has the form \99.
A hex value character has the form 0xFF.
timeout
<milliseconds>
Disconnects when no data has been received on the line
(serial port) for the
specified length of time.
<milliseconds> = timeout in milliseconds.
write
Stores the current configuration in permanent memory.
disconnect (tunnel-disconnect:3) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling
connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is
closed.
flush stop character disable
Forwards the stop character from the Line to the network.
flush stop character enable
Prevents the stop character from the Line from being
forwarded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not
asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling
sessions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.