Lenovo ThinkCentre M51 Hardware Maintenance Manual - Page 50
lists, physical, specifications.
View all Lenovo ThinkCentre M51 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Types 8098, 8171, 8172, 8173, 8424, and 8425 This section lists the physical specifications. Dimensions Airflow Width: 12.2 inches (310 mm) Height: 3.35 inches (85 mm) Approximately 14 cubic feet (0.45 cubic meters) per minute Depth: 14.1 inches (358 mm) Weight Minimum configuration as shipped: 7.3 kg (16 lbs) Maximum configuration as shipped: 8.5 kg (18.7 lbs) Environment Air temperature: Operating at 0 - 3000 ft (914.4 m): 10° to 35°C (50° to 95°F) Operating at 3000 ft - 7000 ft (2134 m): 10° to 32°C (50° to 89.6°F) Non-operating: 10° to 43°C (50° to 110°F) Humidity: Operating: 8% to 80% Non-operating: 8% to 80% Transit: 8% to 90% Maximum altitude: 7000 ft (2133.6 m) Electrical input Input voltage: Low range: Minimum: 90 V ac Maximum: 137 V ac Input frequency: 50/60 Hz Voltage switch setting: 115 V ac High range: Minimum: 180 V ac Maximum: 265 V ac Input frequency: 50/60 Hz Voltage switch setting: 230 V ac Input kilovolt-amperes (kVA) (approximate): Minimum configuration as shipped: 0.09 kVA Maximum configuration: 0.23 kVA Heat output (approximate) in British thermal units (Btu) per hour: Minimum configuration: 205.8 Btu/hr (60 watts) Acoustical noise-emission values Note: In this computer, fan speed is controlled by temperature, configuration, and software. Actual noise-emission values might be different from the stated values depending on the number of fans and the speed of the fans. Average sound-pressure levels for computers with a microprocessor that runs at or below 2.8 GHz: At operator position - 0.5 meters: Idle: 30 dBA Operating: 34 dBA At bystander position - 1 meter (3.3 ft): Idle: 26 dBA Operating: 29 dBA Declared (upper limit) sound-power levels: Idle: 4.0 bels Operating: 4.3 bels Average sound-pressure levels for computers with a microprocessor that runs at greater than 2.8 GHz: At operator position - 0.5 meters: Idle: 31 dBA Operating: 34 dBA At bystander position - 1 meter (3.3 ft): Idle: 26 dBA Operating: 29 dBA Declared (upper limit) sound-power levels: Idle: 4.0 bels Operating: 4.3 bels Note: These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate. Maximum configuration: 548.8 Btu/hr (160 watts) 44 Hardware Maintenance Manual