ADDITIONAL FEATURES CONTROL BOARD OVERVIEW CONTROL BOARD OVERVIEW SET OPEN Button SET CLOSE Button MOVE GATE Button BIPART DELAY Switch LEARN Button TIMER-TO-CLOSE dial REVERSAL FORCE dial TEST BUTTONS STATUS LEDs The SET OPEN button sets the OPEN limit. See Adjust Limits section. The SET CLOSE button sets the CLOSE limit. See Adjust Limits section. The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section. The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section. The LEARN RADIO button is for programming remote controls and the network. The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF. NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR's). The REVERSAL FORCE dial adjusts the force. See Force Adjustment section. The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE). The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section. RESET ALARM Open A Close Stop B Com C Fire Dept Com D Exit Com E Shadow Com F Close Eyes Interrupt G Close Edge (+) Close Edge (-) H Open Eyes/Edge (+) Open Eyes/Edge (-) I 3 Button Station Fire Dept. Exit Loop Shadow Loop Close Eyes/ Interrupt Loop Close Edge Open Eyes/Edge Comm Link Data A Comm Link Data B Lock N.C. (Maglock) Com Lock N.O. (Solenoid) Com (-) AccPower +24 Vdc Com (-) AccPower +24 Vdc J Comm Link K Mag and L Solenoid Lock Acc. Power M Switched ON with gate motion. Always ON with expansion board connected. Switches Off to save N battery power if expansion board disconnected. Always ON 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

26
CONTROL BOARD OVERVIEW
ADDITIONAL FEATURES
CONTROL BOARD OVERVIEW
SET OPEN Button
The SET OPEN button sets the OPEN limit. See Adjust Limits section.
SET CLOSE Button
The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
MOVE GATE Button
The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
BIPART DELAY Switch
The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section.
LEARN Button
The LEARN RADIO button is for programming remote controls and the network.
TIMER-TO-CLOSE dial
The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the
TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the
TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE:
Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate.
The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR’s).
REVERSAL FORCE dial
The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
TEST BUTTONS
The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
STATUS LEDs
The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section.
ALARM
RESET
Open
Close
Stop
Com
Com
Com
Com
Interrupt
Close Edge (+)
Fire Dept
Exit
Shadow
Close Eyes
Close Edge (-)
Comm Link Data A
Comm Link Data B
Open Eyes/Edge (+)
Open Eyes/Edge (-)
Lock N.C. (Maglock)
Com
Lock N.O. (Solenoid)
Com (-)
AccPower +24 Vdc
Com (-)
AccPower +24 Vdc
3 Button
Station
Fire Dept.
Exit Loop
Shadow Loop
Close Eyes/
Interrupt Loop
Comm Link
Close Edge
Open Eyes/Edge
Mag and
Solenoid Lock
A
B
C
D
E
F
G
H
I
J
K
L
M
N
Switched ON with gate motion. Always ON with
expansion board connected. Switches Off to save
battery power if expansion board disconnected.
Always ON
Acc. Power