LiftMaster CSW24V CSW24V Manual - Page 37
Input Leds, Status Leds, Diagnostic Codes Leds, Control Board Leds
View all LiftMaster CSW24V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
TROUBLESHOOTING CONTROL BOARD LEDS CONTROL BOARD LEDS # BLINKS 1 BLINK 2 BLINKS 3 BLINKS 5 BLINKS 6 BLINKS 7 BLINKS 12 BLINKS DIAGNOSTIC CODES LEDS YELLOW DIAGNOSTIC LED MEANING CORRECTION Low Power Mode (not an error) ID resistor failure Check ID resistor wiring, clear limit settings and reset limits Exceeded Maximum Check gate travel, if necessary adjust Run Timer force setting RPM (obstruction) Check for obstruction, if necessary adjust force setting Current (obstruction) Check for obstruction, if necessary adjust force setting Position failure Check gate travel, clear limit settings and reset limits Loop Error One of the loops is in error. Refer to the loop detector to determine the error. RED DIAGNOSTIC LED # BLINKS MEANING CORRECTION 2 BLINKS Current Sense Motor control circuit fault, replace control board 3 BLINKS FET Failure Motor control circuit fault, replace control board 4 BLINKS RAM Failure Memory failure, replace control board 5 BLINKS Flash Memory Failure Memory failure, replace control board 6 BLINKS EEPROM Failure Memory failure, replace control board 7 BLINKS Watchdog Failure Controller failure, replace control board 8 BLINKS Brownout Check power harness or line voltage 9 BLINKS Fail Control Board failure 10-14 BLINKS Software Failure Cycle power to the control board. If continues replace control board. STATUS LEDS INPUT POWER OFF OFF state ON AC charger or Solar power available BATT OFF CHARGING ON Not charging Trickle charge FAST BLINK High current charge FASTER BLINK Over voltage error TIMER OFF The timer is disabled ON The timer is enabled MEDIUM BLINK The timer is running FAST BLINK The timer is paused FASTER BLINK The timer is cancelled GATE MOVING OFF The gate is stopped ON The gate is opening or closing FASTEST BLINK The operator is in E2 BATT LOW OFF No battery error ON Battery low error MEDIUM BLINK Battery critically low error FAST BLINK Battery disconnected error FASTEST BLINK Charging, extreme temperature, or over voltage error ACC PWR OVLD OFF OFF state ON Accessory overload protector opened OPEN INPUT CLOSE INPUT STOP INPUT FIRE DEPT INPUT OPEN SAFETY INPUT CLOSE SAFETY INPUT INPUT LEDS OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator OFF Input inactive ON Input active BLINK Input active on other operator 35